Amana fault codes

40 documented codes for Amana furnaces and air conditioners, each cited to the manufacturer's own manual. Amana and Goodman are both Daikin Comfort Technologies brands built in Waller, TX on the same platforms and the same integrated control boards. One installation manual covers both, using a wildcard model number (for example *MVC96 = GMVC96 and AMVC96), so a code means the same thing on either brand. Daikin-branded furnaces of the same generation use these controls too..

Furnace codes

CodeMeaningSeverity
11 flash, then a pause, repeatingIgnition lockoutSoft lockout
22 flashes, then a pause, repeatingPressure switch stuck closedSoft lockout
33 flashes, then a pause, repeatingPressure switch openSoft lockout
44 flashes, then a pause, repeatingOpen limit switchWarning
55 flashes, then a pause, repeatingFlame sensed when there should be noneSafety fault
66 flashes, then a pause, repeatingOpen rollout limitSafety fault
77 flashes, then a pause, repeatingLow flame sense signalWarning
88 flashes, then a pause, repeatingIgniter relay faultHard lockout
99 flashes, then a pause, repeatingTwinning faultSoft lockout
1010 flashes, then a pause, repeatingOpen fuseHard lockout
1111 flashes, then a pause, repeatingIgniter openHard lockout
1212 flashes, then a pause, repeatingInducer relay error or improper groundingHard lockout
continuous rapid flashcontinuous rapid flashReversed polaritySoft lockout
continuous oncontinuous onNormal operationStatus
offoffNo light at all on the control boardHard lockout
EE0Ignition lockoutSoft lockout
EE1Low-stage pressure switch was already closed when the heat cycle started, so the control will not light the burnersSoft lockout
EE2Low-stage pressure switch never closedSoft lockout
EE3High limitWarning
EE4Flame was detected when there was no call for heatSafety fault
EE5The fuse on the control board has blown, so there is no 24 volt control power and the furnace will not runHard lockout
EE6Flame sense signal is weakWarning
EE7Problem with the igniter circuitHard lockout
EE8High-stage pressure switch was already closed when the heat cycle startedWarning
EE9High-stage pressure switch never closed, so the furnace will not go to high fireWarning
E10Grounding faultSoft lockout
E11Rollout switch is openSafety fault
EEALine polarity is reversedSoft lockout
EEbThe control board is not energizing the gas valve when it should beHard lockout
EECThe gas valve is energized when it should be offSafety fault
EEdAuxiliary limit switch in the blower compartment is openWarning
EEEThe furnace control board detected an internal fault in itself and stoppedHard lockout
EEHTwinning errorSoft lockout
EEJInducer motor relay errorHard lockout
EELIgniter relay faultHard lockout
EEnIgniter openHard lockout
EbLThe circulator blower motor is drawing far less current than expected after the heat-on delay, so the control locks the furnace outHard lockout
nonEThe display shows 'nonE' or nothing at all - the control has no power, or the board is deadHard lockout
EALOn an R-32 refrigerant system, the leak sensor detected refrigerant and put the furnace into mitigation mode - the blower runs to disperse it and normal heating is suspendedSafety fault

Air Conditioner codes

CodeMeaningSeverity
EEFThe condensateWarning