HVAC Code Lookup

Amana Furnace Code 2

Soft lockoutShown as: 2 flashes, then a pause, repeating

Pressure switch stuck closed. The control saw the vent pressure switch already closed before the draft inducer started, so it will not light the burners.

Manual wording: “Pressure Switch stuck Closed

Documented for: Amana AMS8, AMH8, ADS8, ADH8, AMEH8, AMES80, ACES80, AMSS92, AMSS96, ACSS96 (single red diagnostic LED)

Likely causes, most common first

  1. Induced draft blower pressure switch contacts sticking
  2. Shorts in the pressure switch circuit
  3. Induced draft blower is not operating

What you can safely check yourself

  • Turn the furnace off at its power switch for about 30 seconds and back on once to see if the code clears

When to call a technician

A stuck pressure switch is a safety-proving device. It must be tested and replaced by a technician - never jumpered or bypassed.

A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.