HVAC Code Lookup

Lennox fault codes

44 documented codes for Lennox furnaces, each cited to the manufacturer's own manual. Find your code in the table, then jump to what it means, the likely causes, what you can safely check, and when to call a technician.

Lennox furnaces use two different diagnostic systems. Merit/Elite 80-95% single- and two-stage units (ML180, ML193, EL195, EL296E) use a SureLight integrated control with a single red LED that flashes a count (1-13). Variable-capacity and communicating units (SLP98V, SLP99V, SL280V, EL296V, EL296E) use a seven-segment display that shows alphanumeric alert codes (E105, E200, E223, E292 ...). The E-code set is shared across the iComfort/SureLight variable-capacity control family, so the same code number means the same thing on an SLP98UHV and an EL296UHE. Armstrong Air, AirEase, Concord and Ducane are Allied Air brands also owned by Lennox International but use different control boards and a different code list - do not assume these codes carry over.

Furnace codes

CodeMeaningSeverity
11 rapid flash (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe 120-volt line power feeding the furnace has hot and neutral reversedWarning
22 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe control does not see an acceptable earth groundWarning
33 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe burners failed to light during a heat call, or a flame that was lit went out before the heat demand was satisfiedWarning
44 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe flame signal the control reads back from the flame sensor is too weakWarning
55 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsWatchguard lockoutSoft lockout
77 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe primary or secondary limit switch is open, meaning the furnace got too hotSoft lockout
88 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe flame rollout switch is openSafety fault
99 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe pressure prove switch did not close when the combustion air inducer started, or it opened part way through the heat demandWarning
1010 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsWatchguard lockout because the pressure switch opened five times during a single heating demandSoft lockout
1111 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe pressure switch contacts were already closed before the combustion air inducer was turned onWarning
1212 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe control is sensing flame when the gas valve is not energizedSafety fault
1313 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeatsThe 120-volt supply to the furnace is below the acceptable rangeWarning
E105Device communication problemWarning
E110Low line voltageWarning
E111Line voltage polarity reversedWarning
E112Ground not detectedWarning
E113High line voltageWarning
E115Low 24 volt control powerWarning
E124The furnace has not heard from the communicating thermostat for more than three minutesWarning
E125The control failed its own self-checkHard lockout
E200Hard lockoutSafety fault
E203The furnace capacity or size has not been programmed into the controlHard lockout
E204Gas valve mis-wiredSafety fault
E205The gas valve control relay contact on the board is shorted, meaning the control cannot reliably shut the gas valve off through that relaySafety fault
E207The hot surface ignitor is sensed as openSoft lockout
E223The low pressure switch failed to close when it should haveWarning
E224The low pressure switch failed closedWarning
E225The high pressure switch failed to closeWarning
E226The high pressure switch failed closedWarning
E227The low pressure switch opened during the trial for ignition or while the furnace was runningWarning
E229Information onlyStatus
E240Low flame current while the furnace is runningWarning
E241Flame sensed out of sequenceSafety fault
E250The limit switch circuit is open, meaning the furnace overheatedSoft lockout
E270Soft lockoutSoft lockout
E271Soft lockoutSoft lockout
E273Soft lockoutSoft lockout
E274Soft lockoutSoft lockout
E290Ignitor circuit faultSoft lockout
E291Restricted air flowWarning
E292The indoor blower motor is unable to startHard lockout
E310Discharge air temperature sensor failureWarning
E311The furnace has reduced its heat rate to match the airflow the blower can actually deliverWarning
E312Restricted air flow in cooling or continuous fan modeWarning

Lennox furnace code 1: The 120-volt line power feeding the furnace has hot and neutral reversed

WarningShown as: 1 rapid flash (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The 120-volt line power feeding the furnace has hot and neutral reversed. The SureLight control senses line polarity and will not run the burners until the polarity is correct.

Manual wording: “1 - Reverse Line Voltage Polarity”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Hot and neutral wires reversed at the furnace junction box
  2. Reversed polarity in the branch circuit or receptacle feeding the furnace

What you can safely check yourself

  • Confirm the furnace disconnect switch and the breaker feeding the furnace are on
  • Turn the furnace power switch off for 30 seconds and back on once to see whether the code returns

When to call a technician

Correcting line voltage polarity means working inside the furnace junction box or the branch circuit. This is a licensed electrician or HVAC technician job.

Sources

Lennox furnace code 2: The control does not see an acceptable earth ground

WarningShown as: 2 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The control does not see an acceptable earth ground. The SureLight flame-sensing circuit references chassis ground, so the furnace will not run without one.

Manual wording: “2 - Improper Earth Ground”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Ground wire missing, loose or corroded at the furnace junction box
  2. Furnace chassis not bonded to a proper earth ground

What you can safely check yourself

  • Confirm the furnace disconnect switch and breaker are on
  • Turn the furnace power switch off for 30 seconds and back on once to see whether the code returns

When to call a technician

Establishing or repairing the earth ground is electrical work inside the unit. Have a licensed electrician or HVAC technician verify and correct the ground.

Sources

Lennox furnace code 3: The burners failed to light during a heat call, or a flame that was lit went out before the heat demand was satisfied

WarningShown as: 3 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The burners failed to light during a heat call, or a flame that was lit went out before the heat demand was satisfied.

Manual wording: “3 - Burner failed to light, or lost flame during heat demand”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. No gas supply to the furnace, or the manual gas valve is closed
  2. Dirty or failed flame sensor so the control cannot prove the flame
  3. Failed or cracked hot surface ignitor
  4. Condensate or vent restriction interrupting the burner cycle

What you can safely check yourself

  • Check that other gas appliances in the house (range, water heater) are working, which tells you whether gas is being delivered
  • Check that the furnace door is fully seated, since the door switch must be closed for the furnace to fire
  • Check the outdoor intake and exhaust pipes for snow, ice, leaves or nesting debris
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

If the code returns, the ignitor, flame sensor, gas valve or gas pressure needs to be tested. Do not open the burner compartment or touch the gas valve yourself.

Sources

Lennox furnace code 4: The flame signal the control reads back from the flame sensor is too weak

WarningShown as: 4 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The flame signal the control reads back from the flame sensor is too weak. The burner may still be lighting, but the control is warning that the flame-proving signal is marginal.

Manual wording: “4 - Low Flame Signal - check flame sensor”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Flame sensor rod coated with oxide or scale
  2. Poor unit ground, which lowers the measurable flame current
  3. Burner or manifold problem producing a weak or lifting flame

What you can safely check yourself

  • Check and replace the air filter, since poor airflow can distort the flame
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

Cleaning or replacing the flame sensor and measuring flame current in microamps requires opening the burner compartment and using a meter. That is a technician job.

Sources

Lennox furnace code 5: Watchguard lockout

Soft lockoutShown as: 5 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

Watchguard lockout. The burners failed to light after the control used up its maximum number of ignition retries or recycles, so the furnace has locked out.

Manual wording: “5 - Watchguard - burner failed to light, exceeded maximum number of retries or recycles.”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. No gas supply, or gas pressure too low to light the burners
  2. Failed hot surface ignitor
  3. Flame sensor unable to prove the flame after repeated lights
  4. Vent or combustion air restriction cutting the ignition sequence short

What you can safely check yourself

  • Check that other gas appliances in the house are working
  • Check the outdoor intake and exhaust pipes for snow, ice or debris blockage
  • Check that the furnace door is fully seated
  • Turn the furnace power switch off for 30 seconds and back on once to clear the lockout, one time only

When to call a technician

A repeated Watchguard lockout means the furnace has already tried and failed to light several times. Stop resetting it and have a technician find out why it will not light.

Sources

Lennox furnace code 7: The primary or secondary limit switch is open, meaning the furnace got too hot

Soft lockoutShown as: 7 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The primary or secondary limit switch is open, meaning the furnace got too hot. If the limit stays open longer than three minutes the control goes into Watchguard mode.

Manual wording: “7 - Primary or Secondary Limit Open or Watchguard Mode - Limit Switch Open longer than 3 minutes”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Dirty air filter restricting airflow across the heat exchanger
  2. Closed, blocked or undersized supply and return registers
  3. Blower not moving enough air, or a failed blower motor
  4. Restricted or collapsed return duct

What you can safely check yourself

  • Check the air filter and replace it if it is dirty
  • Make sure supply and return registers throughout the house are open and not blocked by furniture or rugs
  • Check that the return grille is not covered
  • Turn the furnace power switch off for 30 seconds and back on once after the furnace has cooled

When to call a technician

If the code comes back after a clean filter and open vents, the limit is tripping for a real reason. Never jumper or bypass a limit switch. Have a technician check airflow, blower operation and firing rate.

Sources

Lennox furnace code 8: The flame rollout switch is open

Safety faultShown as: 8 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The flame rollout switch is open. This safety switch trips when flame or hot combustion gas escapes the burner box instead of going up the heat exchanger.

Manual wording: “8 - Rollout Switch Open”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Blocked or restricted vent or flue
  2. Combustion air inducer not moving enough air
  3. Cracked or plugged heat exchanger
  4. Blocked burners or misaligned burner flames

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice, leaves or nesting debris
  • Check the air filter and replace it if it is dirty

When to call a technician

A tripped rollout switch means combustion gas went where it should not. Do not reset the rollout switch and do not run the furnace. Shut the furnace off and have a technician inspect the vent, inducer and heat exchanger before it runs again. If you smell gas, leave the house and call the gas utility.

Sources

Lennox furnace code 9: The pressure prove switch did not close when the combustion air inducer started, or it opened part way through the heat demand

WarningShown as: 9 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The pressure prove switch did not close when the combustion air inducer started, or it opened part way through the heat demand.

Manual wording: “9 - Pressure Switch failed to close or opened during heat demand”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Blocked or restricted intake or exhaust vent pipe
  2. Plugged condensate drain or trap backing water into the pressure switch tubing
  3. Cracked, kinked or disconnected pressure switch hose
  4. Weak or failed combustion air inducer

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice, leaves or nesting debris
  • Check the condensate drain line and trap for a clog or standing water
  • Check that the furnace door is fully seated
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

If the vent is clear and the drain is clear and the code stays, the pressure switch, its tubing or the inducer needs testing. Never jumper a pressure switch.

Sources

Lennox furnace code 10: Watchguard lockout because the pressure switch opened five times during a single heating demand

Soft lockoutShown as: 10 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

Watchguard lockout because the pressure switch opened five times during a single heating demand. The furnace has given up on that heat call.

Manual wording: “10 - Watchguard - Pressure Switch opened 5 times during one heat demand”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Partially blocked intake or exhaust vent
  2. Plugged condensate drain or trap
  3. Marginal or failing combustion air inducer
  4. Loose or wet pressure switch tubing

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice or debris
  • Check the condensate drain line and trap for a clog
  • Turn the furnace power switch off for 30 seconds and back on once, one time only

When to call a technician

Five pressure switch trips in one cycle points at a venting, drain or inducer problem a technician needs to measure. Do not bypass the switch.

Sources

Lennox furnace code 11: The pressure switch contacts were already closed before the combustion air inducer was turned on

WarningShown as: 11 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The pressure switch contacts were already closed before the combustion air inducer was turned on. The control will not light the burners because it cannot prove the vent is actually drawing.

Manual wording: “11 - Pressure Switch stuck closed prior to activation of combustion air inducer”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Pressure switch stuck closed
  2. Pressure switch tubing routed or connected incorrectly
  3. Shorted pressure switch wiring

What you can safely check yourself

  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

A pressure switch that reads closed at rest is a failed safety device and has to be replaced by a technician. It must never be jumpered out.

Sources

Lennox furnace code 12: The control is sensing flame when the gas valve is not energized

Safety faultShown as: 12 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The control is sensing flame when the gas valve is not energized. Either flame is present when it should not be, or the flame-sensing circuit is reading falsely.

Manual wording: “12 - Flame Sensed without gas valve energized”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Gas valve leaking through and allowing gas to burn when it should be closed
  2. Flame sense circuit or control board fault reading a false flame signal

What you can safely check yourself

  • Turn the furnace power switch off at the switch beside the furnace

When to call a technician

The manual's own instruction for a false flame condition is to shut off the gas and check the gas valve for a leak. Turn the furnace off and call a technician. If you smell gas, leave the house first and call the gas utility from outside.

Sources

Lennox furnace code 13: The 120-volt supply to the furnace is below the acceptable range

WarningShown as: 13 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats

The 120-volt supply to the furnace is below the acceptable range.

Manual wording: “13 - Low Line Voltage”

Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01

Likely causes, most common first

  1. Utility supply voltage low or a brownout condition
  2. Undersized or loose branch circuit wiring feeding the furnace
  3. Loose connection at the disconnect or junction box

What you can safely check yourself

  • Check whether other appliances and lights in the house are also acting up, which suggests a house-wide supply problem
  • Check that the breaker feeding the furnace is fully on

When to call a technician

Measuring and correcting supply voltage is electrical work. Have an electrician or HVAC technician verify the voltage at the unit.

Sources

Lennox furnace code E105: Device communication problem

Warning

Device communication problem. The furnace control sees no other devices on the communication bus, so the thermostat, furnace and outdoor unit are not talking to each other.

Manual wording: “Device communication problem - No other devices on BUS (Communication system).”

Documented for: SLP98UHV series and other Lennox communicating furnaces with a seven-segment diagnostic display

Likely causes, most common first

  1. Miswired or loose communication bus connections between thermostat, furnace and outdoor unit
  2. A high voltage source of electrical noise near the system, such as a welder
  3. Broken or damaged thermostat wiring

What you can safely check yourself

  • Check that the thermostat display is on and, if it is battery powered, that the batteries are good
  • Check that the furnace door is fully seated and the furnace power switch and breaker are on
  • Turn power to the furnace off for 30 seconds and back on once

When to call a technician

Tracing communication bus wiring between the thermostat, furnace and outdoor unit is a technician job.

Source

Lennox furnace code E110: Low line voltage

Warning

Low line voltage. The 120-volt supply to the furnace is lower than the unit nameplate rating.

Manual wording: “Low line voltage. Line Voltage Low (Voltage lower than nameplate rating). Check power line voltage and correct.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Utility supply voltage low or a brownout condition
  2. Undersized or loose branch circuit wiring feeding the furnace

What you can safely check yourself

  • Check whether lights and other appliances in the house are also dimming or misbehaving
  • Check that the breaker feeding the furnace is fully on

When to call a technician

Have an electrician or HVAC technician measure the supply voltage at the unit and correct the source of the low voltage.

Sources

Lennox furnace code E111: Line voltage polarity reversed

Warning

Line voltage polarity reversed. Hot and neutral are swapped in the 120-volt supply to the furnace.

Manual wording: “Line voltage polarity reversed. Reverse line power voltage wiring. System resumes normal operation 5 seconds after fault recovered.”

Documented for: EL296UHE series

Likely causes, most common first

  1. Hot and neutral reversed at the furnace junction box
  2. Reversed polarity in the branch circuit feeding the furnace

What you can safely check yourself

  • Check that the furnace disconnect switch and breaker are on
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

Reversing the line power wiring back to correct polarity is work inside the junction box. Call a licensed electrician or HVAC technician.

Source

Lennox furnace code E112: Ground not detected

Warning

Ground not detected. The control cannot find a proper earth ground and shuts the system down.

Manual wording: “Ground not detected. System shuts down. Provide proper earth ground. System resumes normal operation 5 seconds after fault recovered.”

Documented for: EL296UHE series

Likely causes, most common first

  1. Ground wire missing, loose or corroded at the furnace
  2. Furnace chassis not bonded to a proper earth ground

What you can safely check yourself

  • Check that the furnace disconnect switch and breaker are on
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

Providing a proper earth ground for the furnace is electrical work. Have an electrician or HVAC technician verify and correct the ground.

Source

Lennox furnace code E113: High line voltage

Warning

High line voltage. The 120-volt supply to the furnace is higher than the unit nameplate rating.

Manual wording: “High line voltage. Line Voltage High (Voltage higher than nameplate rating). Provide power voltage within proper range.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Utility supply voltage running high
  2. Incorrect transformer tap or supply configuration at the building

What you can safely check yourself

  • Check whether other equipment in the house is also affected

When to call a technician

Have an electrician or HVAC technician measure supply voltage and bring it into the proper range.

Sources

Lennox furnace code E115: Low 24 volt control power

Warning

Low 24 volt control power. The control voltage has fallen below the acceptable 18 to 30 volt range. The control restarts if the voltage recovers.

Manual wording: “Low 24V - Control will restart if the error recovers. 24-Volt Power Low (Range is 18 to 30 volts).”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Additional power-robbing accessories connected to the 24 volt transformer
  2. Undersized transformer for the installed system
  3. Shorted or damaged low voltage wiring

What you can safely check yourself

  • Check that the furnace door is fully seated
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

Measuring 24 volt supply, finding the load that is dragging it down, and sizing a replacement transformer is a technician job.

Sources

Lennox furnace code E124: The furnace has not heard from the communicating thermostat for more than three minutes

Warning

The furnace has not heard from the communicating thermostat for more than three minutes. Equipment has lost communication with the thermostat.

Manual wording: “Active communicating thermostat signal missing for more than 3 minutes. Equipment lost communication with the thermostat. Check connections and cycle power on the thermostat.”

Documented for: SLP98UHV series and other Lennox communicating furnaces

Likely causes, most common first

  1. Loose or broken thermostat wiring
  2. Thermostat has lost power or locked up
  3. Communication bus connection problem

What you can safely check yourself

  • Check that the thermostat screen is on and set to Heat with the setpoint above room temperature
  • Cycle power on the thermostat as the manual directs
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

If the code persists after a thermostat power cycle, the communication wiring or thermostat needs to be checked by a technician.

Source

Lennox furnace code E125: The control failed its own self-check

Hard lockout

The control failed its own self-check. This is an internal hardware error on the furnace control board, covering things like flame sense circuit faults and pin shorts. The control restarts if the error clears.

Manual wording: “Control failed self-check, internal error, failed hardware. Will restart if error recovers.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Hardware failure on the integrated furnace control board
  2. Flame sense circuit fault on the board
  3. Electrical noise or a power event that corrupted the control

What you can safely check yourself

  • Turn the furnace power switch off for 30 seconds and back on once to cycle power on the control

When to call a technician

If the code returns after a single power cycle, the control board is failing and needs to be replaced by a technician.

Sources

Lennox furnace code E200: Hard lockout

Safety fault

Hard lockout. The flame rollout circuit is open or was open. The rollout switch trips when flame or hot combustion gas escapes the burner box instead of going into the heat exchanger.

Manual wording: “Hard lockout - Rollout circuit open or previously open. Correct unit cause of rollout trip or replace flame rollout switch and test furnace operation.”

Documented for: SLP98UHV and EL296UHE series

Likely causes, most common first

  1. Blocked or restricted vent or flue
  2. Combustion air inducer not moving enough air
  3. Cracked or plugged heat exchanger
  4. Blocked burners causing flame to roll out of the burner box

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice, leaves or nesting debris
  • Check the air filter and replace it if it is dirty

When to call a technician

The manual's action is to correct the cause of the rollout trip or replace the flame rollout switch and then test furnace operation. Do not reset the rollout switch yourself and do not keep running the furnace. Shut it off and have a technician inspect the vent, inducer and heat exchanger. If you smell gas, leave the house and call the gas utility.

Sources

Lennox furnace code E203: The furnace capacity or size has not been programmed into the control

Hard lockout

The furnace capacity or size has not been programmed into the control. The control does not know what size furnace it is running, so it will not operate.

Manual wording: “Appliance capacity / size is NOT programmed. Invalid unit codes refer to configuration flow chart in installation instructions.”

Documented for: SLP98UHV series

Likely causes, most common first

  1. New or replacement control board installed without the unit size code being set
  2. Invalid unit code entered during setup

When to call a technician

This is a setup step done during installation or after a board replacement. A technician has to select the correct furnace size code from the configuration guide.

Source

Lennox furnace code E204: Gas valve mis-wired

Safety fault

Gas valve mis-wired. The control detects that the gas valve is not wired the way it expects.

Manual wording: “Gas valve mis-wired. Check gas valve operation and wiring. Clears when repaired.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Gas valve wiring connected incorrectly, usually after a service call or valve replacement
  2. Loose or damaged gas valve wiring harness

When to call a technician

Anything involving gas valve wiring is a technician job. Turn the furnace off and have the valve wiring checked and corrected.

Sources

Lennox furnace code E205: The gas valve control relay contact on the board is shorted, meaning the control cannot reliably shut the gas valve off through that relay

Safety fault

The gas valve control relay contact on the board is shorted, meaning the control cannot reliably shut the gas valve off through that relay.

Manual wording: “Gas valve control relay contact shorted. Check wiring on control and gas valve. If wiring is correct, replace control.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Failed gas valve relay on the integrated control board
  2. Incorrect wiring at the control or gas valve

When to call a technician

The manual's action is to check the wiring on the control and gas valve and, if the wiring is correct, replace the control. A shorted gas valve relay is a safety-critical failure. Turn the furnace off and call a technician.

Sources

Lennox furnace code E207: The hot surface ignitor is sensed as open

Soft lockout

The hot surface ignitor is sensed as open. The control cannot pass current through the ignitor, so the burners will not light.

Manual wording: “Hot surface ignitor sensed open. Measure resistance of hot surface ignitor. Replace if open or not within specified range found in IOM.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Cracked or burned out hot surface ignitor
  2. Loose or corroded ignitor connector
  3. Broken ignitor wiring

What you can safely check yourself

  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

The manual's action is to measure the resistance of the hot surface ignitor and replace it if it is open or out of specification. Hot surface ignitors are fragile and sit inside the burner compartment. Have a technician replace it.

Sources

Lennox furnace code E223: The low pressure switch failed to close when it should have

Warning

The low pressure switch failed to close when it should have. The control cannot prove that the combustion air inducer is producing enough draft to safely light the burners.

Manual wording: “Low pressure switch failed open. Check pressure (inches w.c.) of low pressure switch closing on heat call. Inspect vent and combustion air inducer for correct operation and restriction.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Blocked or restricted intake or exhaust vent pipe
  2. Plugged condensate drain or trap backing water into the system
  3. Cracked, kinked or disconnected pressure switch hose
  4. Weak or failing combustion air inducer

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice, leaves or nesting debris
  • Check the condensate drain line and trap for a clog or standing water
  • Check that the furnace door is fully seated
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

The manual's action is to measure pressure switch closing pressure in inches of water column and inspect the vent and combustion air inducer for restriction. That needs a manometer and an open cabinet. Never jumper a pressure switch.

Sources

Lennox furnace code E224: The low pressure switch failed closed

Warning

The low pressure switch failed closed. The switch reads closed when the control expects it to be open, so the control cannot verify draft before lighting.

Manual wording: “Low pressure switch failed closed. Check low pressure switch for closed contacts, measure inches of water column of operating pressure, inspect vent and combustion air inducer for correct operation and restriction.”

Documented for: SLP98UHV and EL296UHE series

Likely causes, most common first

  1. Pressure switch stuck closed
  2. Pressure switch tubing misrouted or blocked
  3. Shorted pressure switch wiring

What you can safely check yourself

  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

A pressure switch stuck closed is a failed safety device. It has to be tested and replaced by a technician, never bypassed.

Sources

Lennox furnace code E225: The high pressure switch failed to close

Warning

The high pressure switch failed to close. On a two-stage or variable-capacity furnace this switch has to close before the unit can fire on high fire.

Manual wording: “High pressure switch failed open. Check pressure (inches w.c.) of high pressure switch closing on heat call. Inspect vent and combustion air inducer for correct operation and restriction.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Blocked or restricted intake or exhaust vent pipe
  2. Plugged condensate drain or trap
  3. Cracked, kinked or disconnected high pressure switch hose
  4. Combustion air inducer not reaching full speed

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice or debris
  • Check the condensate drain line and trap for a clog
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

Measuring switch closing pressure and inspecting the inducer for restriction requires a manometer and an open cabinet. Have a technician do it.

Sources

Lennox furnace code E226: The high pressure switch failed closed

Warning

The high pressure switch failed closed. It reads closed when the control expects it to be open.

Manual wording: “High pressure switch failed closed. Check operation of high pressure switch closing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct operation and restriction.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. High pressure switch stuck closed
  2. Pressure switch tubing misrouted or blocked
  3. Shorted pressure switch wiring

What you can safely check yourself

  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

A pressure switch stuck closed is a failed safety device and must be replaced by a technician, never bypassed.

Sources

Lennox furnace code E227: The low pressure switch opened during the trial for ignition or while the furnace was running

Warning

The low pressure switch opened during the trial for ignition or while the furnace was running. Draft was lost partway through the heat cycle, so the control shut the burners down.

Manual wording: “Low pressure switch open during trial for ignition or run mode.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Partially blocked intake or exhaust vent, including snow or ice at the termination
  2. Plugged condensate drain or trap
  3. Wet, cracked or loose pressure switch tubing
  4. Failing combustion air inducer

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice, leaves or nesting debris
  • Check the condensate drain line and trap for a clog or standing water
  • Check that the furnace door is fully seated
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

If the vent and drain are clear and the code returns, the pressure switch, its tubing or the inducer needs testing with a manometer. Never jumper a pressure switch.

Sources

Lennox furnace code E229: Information only

Status

Information only. The furnace lit on high fire instead of low fire. This happens either because the low pressure switch did not close, so the control sped up the inducer to close both switches and lit on high fire, or because continuous fan was running and the furnace lights on high fire for 60 seconds to warm the heat exchanger faster.

Manual wording: “Ignition on High Fire - Information Only.”

Documented for: EL296UHE series

Likely causes, most common first

  1. Low pressure switch failing to close on a normal low-fire start, often from a partially restricted vent
  2. Continuous fan mode active at the start of the heat call, which is normal behavior

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice or debris if the code shows up repeatedly
  • Check the air filter and replace it if it is dirty

When to call a technician

On its own this code is informational and needs no action. If it appears on every heat call along with pressure switch codes such as E223 or E227, have a technician check the vent and inducer.

Source

Lennox furnace code E240: Low flame current while the furnace is running

Warning

Low flame current while the furnace is running. The control can see flame but the signal from the flame sensor is weaker than it should be.

Manual wording: “Low flame current - Run mode. Check micro-amperes of flame sensor using control diagnostics or field-installed mode. Clean or replace sensor.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Flame sensor rod coated with oxide or scale
  2. Poor unit ground, which lowers measurable flame current
  3. Weak or lifting burner flame

What you can safely check yourself

  • Check and replace the air filter if it is dirty
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

The manual's action is to measure flame sensor current in microamps, clean or replace the sensor, and verify neutral to ground voltage. That is a technician job inside the burner compartment.

Sources

Lennox furnace code E241: Flame sensed out of sequence

Safety fault

Flame sensed out of sequence. The control still sees flame at a point in the cycle when there should be none, which suggests gas is still burning after the valve was told to close.

Manual wording: “Flame sensed out of sequence - Flame still present. Shut off gas. Check for gas valve leak. Replace, if necessary.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Gas valve leaking through and letting gas continue to burn
  2. Flame sense circuit reading a false signal

What you can safely check yourself

  • Turn the furnace power switch off at the switch beside the furnace

When to call a technician

The manual's action is to shut off the gas and check the gas valve for a leak, replacing it if necessary. Turn the furnace off and call a technician right away. If you smell gas, leave the house and call the gas utility from outside.

Sources

Lennox furnace code E250: The limit switch circuit is open, meaning the furnace overheated

Soft lockout

The limit switch circuit is open, meaning the furnace overheated. If the limit does not close within three minutes the unit goes into a one hour soft lockout.

Manual wording: “Limit switch circuit open. Check for proper firing rate on furnace. Ensure there is no blockage in heater. Check for proper air flow. If limit not closed within 3 minutes, unit will go into 1-hour soft lockout.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Dirty air filter restricting airflow across the heat exchanger
  2. Closed, blocked or undersized supply and return registers
  3. Blower not moving enough air
  4. Furnace overfired, or blockage inside the heater

What you can safely check yourself

  • Check the air filter and replace it if it is dirty
  • Make sure supply and return registers throughout the house are open and not blocked by furniture or rugs
  • Check that the return grille is clear
  • After the furnace has cooled, turn the power switch off for 30 seconds and back on once

When to call a technician

The manual's action is to check firing rate, look for blockage and verify proper air flow. If the code comes back after a clean filter and open vents, have a technician measure temperature rise and airflow. Never jumper or bypass a limit switch.

Sources

Lennox furnace code E270: Soft lockout

Soft lockout

Soft lockout. The furnace used up its maximum number of ignition retries and never sensed any flame current, so it stopped trying to light.

Manual wording: “Soft lockout - Exceeded maximum number of retries. No flame current sensed. Check for proper gas flow. Ensure that ignitor is lighting burner. Check flame sensor current.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. No gas supply to the furnace, or the manual gas valve is closed
  2. Ignitor not lighting the burners
  3. Flame sensor not proving the flame
  4. Gas pressure too low

What you can safely check yourself

  • Check that other gas appliances in the house are working, which tells you whether gas is being delivered
  • Check that the furnace door is fully seated
  • Turn the furnace power switch off for 30 seconds and back on once, one time only

When to call a technician

The manual's action is to check gas flow, confirm the ignitor is lighting the burner and check flame sensor current. Stop resetting the furnace and have a technician find out why it will not light.

Sources

Lennox furnace code E271: Soft lockout

Soft lockout

Soft lockout. The furnace used up its ignition retries and the last attempt failed because the pressure switch opened.

Manual wording: “Soft lockout - Exceeded maximum number of retries. Last retry failed due to the pressure switch opening.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Blocked or restricted intake or exhaust vent pipe
  2. Plugged condensate drain or trap
  3. Loose or wet pressure switch tubing
  4. Failing combustion air inducer

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice or debris
  • Check the condensate drain line and trap for a clog
  • Turn the furnace power switch off for 30 seconds and back on once, one time only

When to call a technician

Same diagnosis as E223: the manual calls for measuring pressure switch closing pressure and inspecting the vent and inducer for restriction. Have a technician do it.

Sources

Lennox furnace code E273: Soft lockout

Soft lockout

Soft lockout. The furnace used up its maximum number of recycles and the last one was caused by flame failure, meaning the burner lit but the flame was lost.

Manual wording: “Soft lockout - Exceeded maximum number of recycles. Last recycle due to flame failure.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Dirty flame sensor unable to hold the flame signal
  2. Poor unit ground lowering flame current
  3. Low or unstable gas pressure
  4. Vent or condensate restriction cutting the cycle short

What you can safely check yourself

  • Check that other gas appliances in the house are working
  • Check the outdoor intake and exhaust pipes for snow, ice or debris
  • Turn the furnace power switch off for 30 seconds and back on once, one time only

When to call a technician

The manual's action is to measure flame sensor current, clean or replace the sensor and verify the unit ground. That is a technician job.

Sources

Lennox furnace code E274: Soft lockout

Soft lockout

Soft lockout. The furnace used up its maximum number of recycles and the last one failed because the limit circuit opened, or the limit stayed open longer than three minutes. The unit shuts down for one hour.

Manual wording: “Soft lockout - Exceeded maximum number of recycles. Last recycle failed due to the limit circuit opening or limit remained open longer than 3 minutes.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Dirty air filter restricting airflow
  2. Closed or blocked supply and return registers
  3. Blower not moving enough air
  4. Furnace overfired or blockage inside the heater

What you can safely check yourself

  • Check the air filter and replace it if it is dirty
  • Make sure supply and return registers are open and unblocked
  • After the furnace has cooled, turn the power switch off for 30 seconds and back on once

When to call a technician

The manual's action is to check firing rate and air flow and look for blockage. Repeated limit lockouts need a technician. Never jumper or bypass a limit switch.

Sources

Lennox furnace code E290: Ignitor circuit fault

Soft lockout

Ignitor circuit fault. Either the hot surface ignitor has failed or the circuitry that fires it has failed. The furnace goes into a one hour soft lockout.

Manual wording: “Ignitor circuit fault - Failed ignitor or triggering circuitry. Measure resistance of hot surface ignitor. Replace if open or not within specifications. 1-hour soft lockout.”

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Failed or cracked hot surface ignitor
  2. Failed ignitor triggering circuit on the control board
  3. Loose or damaged ignitor wiring

What you can safely check yourself

  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

The manual's action is to measure ignitor resistance and replace it if it is out of specification. Have a technician do it.

Sources

Lennox furnace code E291: Restricted air flow

Warning

Restricted air flow. The blower is moving fewer cubic feet per minute than the furnace needs even at its minimum firing rate.

Manual wording: “Restricted air flow - Cubic feet per minute is lower than what is needed for minimum firing rate. Check for dirty filter, unit air flow restriction, blower performance.”

Documented for: SLP98UHV series

Likely causes, most common first

  1. Dirty air filter
  2. Restricted, undersized or partially collapsed ductwork
  3. Blower wheel dirty or blower performance degraded
  4. Closed or blocked registers

What you can safely check yourself

  • Check the air filter and replace it if it is dirty
  • Make sure supply and return registers throughout the house are open and unblocked
  • Check that the return grille is not covered

When to call a technician

If a clean filter and open registers do not clear it, the duct system or blower needs to be evaluated by a technician.

Source

Lennox furnace code E292: The indoor blower motor is unable to start

Hard lockout

The indoor blower motor is unable to start. The control commanded the blower to run and it did not turn, typically from seized bearings or a stuck blower wheel.

Manual wording: “Indoor blower motor unable to start - Seized bearings, stuck wheel, etc. Indoor blower motor unable to start (seized bearing, stuck wheel, etc), replace motor or wheel if assembly does not operate or meet performance.”

Documented for: SLP98UHV series and other Lennox variable-speed furnaces with a seven-segment display

Likely causes, most common first

  1. Seized blower motor bearings
  2. Blower wheel stuck or jammed by debris
  3. Failed blower motor module

What you can safely check yourself

  • Check that the furnace door is fully seated
  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

The manual's action is to replace the motor or the wheel if the assembly does not operate or meet performance. Do not reach into the blower compartment. Have a technician replace it.

Source

Lennox furnace code E310: Discharge air temperature sensor failure

Warning

Discharge air temperature sensor failure. The sensor is reading shorted or out of range. There is no error if the sensor is simply disconnected. The code is activated during Field Test mode.

Manual wording: “Discharge error sensor failure - No error if disconnected. Only shown if shorted or out-of-range. Discharge air temperature(DATS) out of range, code is activated during "Field test mode".”

Documented for: SLP98UHV series

Likely causes, most common first

  1. Failed or shorted discharge air temperature sensor
  2. Damaged sensor wiring

What you can safely check yourself

  • Turn the furnace power switch off for 30 seconds and back on once

When to call a technician

Checking sensor resistance against the temperature charts and replacing the sensor is a technician job.

Source

Lennox furnace code E311: The furnace has reduced its heat rate to match the airflow the blower can actually deliver

Warning

The furnace has reduced its heat rate to match the airflow the blower can actually deliver. The blower is in cutback mode because airflow is restricted.

Manual wording: “Heat rate reduced to match indoor blower air flow. Replace filter or repair duct restriction. Furnace blower in cutback mode due to restricted airflow.”

Documented for: SLP98UHV series

Likely causes, most common first

  1. Dirty air filter
  2. Restricted or undersized ductwork
  3. Closed or blocked registers

What you can safely check yourself

  • Check the air filter and replace it if it is dirty
  • Make sure supply and return registers throughout the house are open and unblocked
  • Check that the return grille is not covered

When to call a technician

The manual's action is to replace the filter if needed or repair and add ductwork. If a clean filter does not clear it, the duct system needs a technician.

Source

Lennox furnace code E312: Restricted air flow in cooling or continuous fan mode

Warning

Restricted air flow in cooling or continuous fan mode. The blower is delivering less air than its cfm setting because the variable speed motor has hit its built-in speed and torque limits.

Manual wording: “Restricted air flow in cooling or continuous fan mode is lower than cfm setting. Indoor blower is running at a reduced cubic feet per minute (Cutback Mode).”

Documented for: SLP98UHV series

Likely causes, most common first

  1. Dirty air filter
  2. Restricted or undersized ductwork pushing total external static pressure above 0.8 inches water column
  3. Closed or blocked registers

What you can safely check yourself

  • Check the air filter and replace it if it is dirty
  • Make sure supply and return registers throughout the house are open and unblocked
  • Check that the return grille is not covered

When to call a technician

The manual's action is to replace the filter if needed or repair and add ductwork. If a clean filter does not clear it, static pressure has to be measured by a technician.

Source

How old is this Lennox?

Age changes what a fault code means for you. The same failure is a routine repair on a six-year-old unit and the end of the line on a twenty-year-old one. Your Lennox serial number has the build date in it.

Decode your Lennoxserial number →