HVAC Code Lookup

Trane fault codes

38 documented codes for Trane furnaces, each cited to the manufacturer's own manual. Find your code in the table, then jump to what it means, the likely causes, what you can safely check, and when to call a technician.

Trane and American Standard are both Trane Technologies brands and share the same integrated furnace control (IFC) platforms. Older induced-draft and condensing furnaces (XR80/XR95/XV80/XV95 era) use a single red diagnostic LED that blinks a count; current S-series furnaces (S8B1, S8V2, S9X1/S9X2, S9V2, S9V2-VS) use a two/three-character seven-segment display showing E-codes. American Standard's equivalent models (A801X, A951X, Silver/Gold/Platinum 80 and 95) use the same tables with brand-specific wording.

Looking it up by flash count?

If you counted LED flashes rather than reading a code number, these are the codes that start with that many flashes:

  • 2 flashes: 2 Flashes (System lockout)
  • 3 flashes: 3 Flashes (Draft pressure error)
  • 4 flashes: 4 Flashes (Open high limit device)
  • 5 flashes: 5 Flashes (Flame is being detected when there should be no flame present)
  • 6 flashes: 6 Flashes (The 115 volt AC line and neutral are reversed at the furnace, or the furnace is poorly grounded)
  • 7 flashes: 7 Flashes (Gas valve circuit error)
  • 8 flashes: 8 Flashes (Low flame sense signal)
  • 9 flashes: 9 Flashes (The control is directing the technician to check the igniter circuit and the voltage between line neutral and 24VAC common, which points at an igniter or grounding problem)

Furnace codes

CodeMeaningSeverity
Flashing SlowRed LED flashing slowly and steadilyNormal standbyStatus
Flashing FastRed LED flashing rapidly and steadilyNormal operation with an active call for heatStatus
Continuous ONLED on solid, never blinkingThe integrated furnace controlHard lockout
Continuous OFFLED completely darkThe control board is not receiving powerWarning
2 Flashes2 flashes, pause, repeatSystem lockoutHard lockout
3 Flashes3 flashes, pause, repeatDraft pressure errorSoft lockout
4 Flashes4 flashes, pause, repeatOpen high limit deviceSoft lockout
5 Flashes5 flashes, pause, repeatFlame is being detected when there should be no flame presentSafety fault
6 Flashes6 flashes, pause, repeatThe 115 volt AC line and neutral are reversed at the furnace, or the furnace is poorly groundedWarning
7 Flashes7 flashes, pause, repeatGas valve circuit errorSafety fault
8 Flashes8 flashes, pause, repeatLow flame sense signalWarning
9 Flashes9 flashes, pause, repeatThe control is directing the technician to check the igniter circuit and the voltage between line neutral and 24VAC common, which points at an igniter or grounding problemWarning
E01Internal integrated furnace control failureHard lockout
E2.1Retry exceededHard lockout
E2.2Recycles exceededHard lockout
E2.3The control commanded the first-stage gas valve on and the valve did not energize, ten times in a rowHard lockout
E3.1The first-stage pressure switch is reading closed when the control expects it to be open, which the control calls a shorted pressure switchSoft lockout
E3.2The first-stage pressure switch will not close, so the control cannot prove the draft inducer is moving flue gas and will not open the gas valveSoft lockout
E3.3The second-stage pressure switch is reading closed when the control expects it to be openSoft lockout
E3.4The second-stage pressure switch will not close, so the furnace cannot go to high fireSoft lockout
E04A safety limit has opened: the main thermal limit, a flame rollout switch, or the reverse airflow switchSafety fault
E4.0The high limit switch has opened because the furnace overheatedSoft lockout
E4.1The reverse air-flow limit switch has opened, meaning air is moving through the furnace the wrong way or a downflow/horizontal airflow fault has been sensedSafety fault
E4.2The flame roll-out limit switch has openedSafety fault
E05The control is sensing a flame when there should not be one - for example with the gas valve commanded offSafety fault
E06Line voltage polarity is reversed at the furnace, or the furnace is not properly groundedWarning
E6.1Line and neutral are reversed in the 115 volt supply to the furnaceWarning
E6.2The furnace does not have a good electrical ground, which the control needs in order to sense flame reliablyWarning
E6.3Igniter faultHard lockout
E7.1The first-stage gas valve is energized when the control has commanded it offSafety fault
E7.2The redundant safety relay on the controlSafety fault
E08The flame current the control reads is low but still high enough to keep runningWarning
E09The inducer limit switch or the condensate pressure switch is openSoft lockout
E10The control is not getting a response from the variable-speed inducer motor, or the two microcontrollers on the board cannot talk to each otherHard lockout
E11Gas valve relay faultSafety fault
E12The 5 amp fuse on the integrated furnace control has opened, so 24 volt control power is lostHard lockout
E13The blower motor's horsepower or OEM ID does not match what the furnace's personality module expectsHard lockout
E17The control is not getting a response from the ECM blower motor, so the indoor blower will not runHard lockout

Trane furnace Flashing Slow: Normal standby

StatusShown as: Red LED flashing slowly and steadily

Normal standby. The control board is powered and healthy and the thermostat is not calling for heat.

Manual wording: “Flashing Slow --- Normal - No call for Heat”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Normal operation with no heat call from the thermostat

What you can safely check yourself

  • If the house is cold, check that the thermostat is set to Heat and set above room temperature
  • Check thermostat batteries if it has them

When to call a technician

No service needed. If the thermostat is calling for heat and the LED stays on the slow flash, the thermostat or its wiring is not reaching the furnace and a technician should check it.

Sources

Trane furnace Flashing Fast: Normal operation with an active call for heat

StatusShown as: Red LED flashing rapidly and steadily

Normal operation with an active call for heat. The control has accepted the thermostat's heat request.

Manual wording: “Flashing Fast --- Normal - Call for Heat”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Normal operation during a heating cycle

When to call a technician

No service needed. If the LED flashes fast but no warm air ever arrives, note any code the LED changes to and have a technician diagnose it.

Source

Trane furnace Continuous ON: The integrated furnace control

Hard lockoutShown as: LED on solid, never blinking

The integrated furnace control (IFC) itself has failed. The manual's instruction for this pattern is to replace the control board.

Manual wording: “Continuous ON --- Replace IFC”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Failed integrated furnace control board

What you can safely check yourself

  • Turn the furnace switch off and back on once to confirm the LED really stays solid rather than flashing a code

When to call a technician

This is a board replacement. Call a technician; there is nothing a homeowner can do about a failed integrated furnace control.

Source

Trane furnace Continuous OFF: The control board is not receiving power

WarningShown as: LED completely dark

The control board is not receiving power. The manual's instruction for a dark LED is to check power to the furnace.

Manual wording: “Continuous OFF --- Check Power”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. No line power reaching the furnace
  2. Open circuit breaker or blown fuse
  3. Furnace disconnect switch off
  4. Blower door not fully seated, which opens the door switch

What you can safely check yourself

  • Make sure the main furnace switch (usually a light-switch near the furnace or at the top of the basement stairs) is in the ON position
  • Reset the circuit breaker, or replace a blown fuse
  • Make sure the furnace blower door is fully closed and latched

When to call a technician

If the breaker is on, the switch is on, and the door is closed but the board is still dark, a technician needs to check the transformer, fuse, and wiring.

Sources

Trane furnace 2 Flashes: System lockout

Hard lockoutShown as: 2 flashes, pause, repeat

System lockout. The control tried and failed to establish or hold a flame enough times (retries or recycles exceeded) and has shut the furnace down.

Manual wording: “2 Flashes --- System Lockout (Retries or Recycles exceeded)”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Loss of flame or gas supply failure - the control recycled the ignition sequence and never achieved ignition, so it shut off the gas valve and locked out the system
  2. Ignition failure at the burners
  3. Flame sensed then repeatedly lost during the heating cycle

What you can safely check yourself

  • Check that other gas appliances in the house are working, which tells you whether gas is reaching the home at all
  • Reset once by cycling power: turn the system power off, then on, then off, then on again within 30 seconds at the furnace switch or thermostat

When to call a technician

If the furnace locks out again after one reset, stop resetting it. Repeated ignition failure means the igniter, flame sensor, gas valve, or gas pressure needs a technician.

Source

Trane furnace 3 Flashes: Draft pressure error

Soft lockoutShown as: 3 flashes, pause, repeat

Draft pressure error. The pressure switch that proves the draft inducer is moving flue gas is not in the state the control expects, so the control will not open the gas valve.

Manual wording: “3 Flashes --- Draft Pressure Error - Possible problems a) Venting problem b) Pressure switch problem c) Inducer problem”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Venting problem
  2. Pressure switch problem
  3. Inducer problem
  4. Excessive combustion pressure (wind in excess of 40 m.p.h.), vent or flue blockage
  5. Condensate drain blockage from debris, improper draining, or freezing condensate (condensing models)
  6. Induced draft blower failure - if pressure is not sensed, the contacts remain open and will not allow the gas valve to open

What you can safely check yourself

  • Go outside and check the PVC intake and exhaust pipes for snow, ice, leaves, or a bird/insect nest blocking them
  • Check the condensate drain line and trap for a clog, and make sure any condensate pump is working and not full
  • Check that the vent terminations are clear after heavy wind or snow

When to call a technician

If the vent and intake pipes are clear and the drain is not clogged, the pressure switch, its tubing, or the inducer motor needs a technician. Never jumper or bypass a pressure switch.

Source

Trane furnace 4 Flashes: Open high limit device

Soft lockoutShown as: 4 flashes, pause, repeat

Open high limit device. A temperature limit switch has opened because the furnace got too hot, which closes the gas valve and stops the burners.

Manual wording: “4 Flashes --- Open High Limit Device”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Restricted airflow across the heat exchanger - the manual's own limit checkout deliberately trips the limit by 'blocking the return air', which is what a dirty filter or blocked returns do in service
  2. Blocked vent or combustion air inlet terminations (the manual's burner-box limit reset step says 'The vent and combustion air inlet terminations should be checked for blockage')
  3. Faulty limit switch

What you can safely check yourself

  • Check the air filter and clean or replace it if it is dirty
  • Check that supply registers and return grilles are open and not blocked by furniture or rugs
  • Check the outdoor vent and combustion air intake terminations for blockage

When to call a technician

If the code comes back after a clean filter and open vents, the furnace is overheating for a reason a technician must diagnose. The burner-box manual-reset limit 'must be reset by a qualified servicer' per the manual - do not press or bypass safety limits yourself.

Sources

Trane furnace 5 Flashes: Flame is being detected when there should be no flame present

Safety faultShown as: 5 flashes, pause, repeat

Flame is being detected when there should be no flame present. The control sees a flame signal with the gas valve commanded off.

Manual wording: “5 Flashes --- Flame sensed when no flame should be present”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Flame sensed when no flame should be present
  2. Gas valve leaking through or slow to close
  3. Faulty flame sensing circuit

What you can safely check yourself

  • Turn the furnace switch off and leave it off
  • If you smell gas, leave the house and call the gas utility from outside

When to call a technician

Call a technician. A false or lingering flame signal points at the gas valve or flame-proving circuit and is not a homeowner repair.

Source

Trane furnace 6 Flashes: The 115 volt AC line and neutral are reversed at the furnace, or the furnace is poorly grounded

WarningShown as: 6 flashes, pause, repeat

The 115 volt AC line and neutral are reversed at the furnace, or the furnace is poorly grounded. The control needs correct polarity and a good ground to sense flame.

Manual wording: “6 Flashes --- 115 Volt AC power reversed or Poor Grounding”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. 115 Volt AC power reversed
  2. Poor grounding

What you can safely check yourself

  • Note whether the code appeared right after electrical work, a new outlet, or a generator was used

When to call a technician

Call a technician or electrician. Correcting line polarity and grounding is electrical work inside the furnace and the panel.

Source

Trane furnace 7 Flashes: Gas valve circuit error

Safety faultShown as: 7 flashes, pause, repeat

Gas valve circuit error. The control has detected a fault in the circuit that drives the gas valve.

Manual wording: “7 Flashes --- Gas valve circuit error”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Gas valve circuit error

What you can safely check yourself

  • Turn the furnace switch off and leave it off until a technician has looked at it

When to call a technician

Call a technician. Anything involving the gas valve or its wiring is a licensed-tech job.

Source

Trane furnace 8 Flashes: Low flame sense signal

WarningShown as: 8 flashes, pause, repeat

Low flame sense signal. The furnace is running, but the flame current the control reads is weak, so it is warning that flame proving is marginal.

Manual wording: “8 Flashes --- Low flame sense signal”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Low flame sense signal

What you can safely check yourself

  • Note whether the furnace is still heating; this code usually appears while the furnace is still running

When to call a technician

Schedule service. A weak flame signal usually means the flame sensor needs cleaning or the burner flame is not right, and if it drops further the furnace will lock out. Cleaning the flame sensor means working in the burner compartment, so leave it to a technician.

Source

Trane furnace 9 Flashes: The control is directing the technician to check the igniter circuit and the voltage between line neutral and 24VAC common, which points at an igniter or grounding problem

WarningShown as: 9 flashes, pause, repeat

The control is directing the technician to check the igniter circuit and the voltage between line neutral and 24VAC common, which points at an igniter or grounding problem.

Manual wording: “9 Flashes --- Check Ignitor circuit and Line "N" to 24VAC "Common" voltage (< 2volts) (possible grounding problem)”

Documented for: *UH1 / *DH1 condensing furnaces (XR 95 family) and other Trane furnaces using the LED-only integrated furnace control

Likely causes, most common first

  1. Igniter circuit fault
  2. Possible grounding problem (Line "N" to 24VAC "Common" voltage should be under 2 volts)

What you can safely check yourself

  • Note whether the furnace tries to start and never lights

When to call a technician

Call a technician. Checking the igniter circuit and neutral-to-common voltage requires meters inside a live control compartment.

Source

Trane furnace code E01: Internal integrated furnace control failure

Hard lockout

Internal integrated furnace control failure. The control's own processor has lost its interrupt or hit another internal error.

Manual wording: “Loss of the IRQ or other internal failures (Internal IFC error)”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces with the seven-segment IFC display

Likely causes, most common first

  1. Loss of the IRQ or other internal failures (Internal IFC error)

What you can safely check yourself

  • Turn the furnace switch off, wait a minute, and turn it back on once to see whether the code clears

When to call a technician

If E01 returns, the control board needs to be replaced by a technician.

Sources

Trane furnace code E2.1: Retry exceeded

Hard lockout

Retry exceeded. The furnace tried to light and never proved a flame, so the control has locked out for one hour.

Manual wording: “Retry Exceeded (Flame never sensed, one hour lockout after 3 times)”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces with the seven-segment IFC display

Likely causes, most common first

  1. Flame never sensed on repeated ignition attempts
  2. No gas or interrupted gas supply
  3. Failed igniter
  4. Dirty or failed flame sensor

What you can safely check yourself

  • Check that other gas appliances in the house work, which tells you gas is reaching the home
  • Check that the manual gas shutoff at the furnace has not been left closed after service
  • Reset once by turning the furnace switch off and back on

When to call a technician

If the furnace locks out again, stop resetting it. Repeated failure to light needs a technician to check the igniter, flame sensor, gas valve, and gas pressure.

Sources

Trane furnace code E2.2: Recycles exceeded

Hard lockout

Recycles exceeded. The burner lit but the flame was lost during the cycle, repeatedly, so the control locked out for one hour.

Manual wording: “Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times)”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces with the seven-segment IFC display

Likely causes, most common first

  1. Flame sensed then lost, ten times
  2. Marginal flame signal or dirty flame sensor
  3. Low or unstable gas pressure
  4. On the S9V2-VS, the first-stage pressure switch opening ten times during a cycle

What you can safely check yourself

  • Check the air filter and replace it if dirty
  • Check the outdoor intake and exhaust terminations for blockage
  • Reset once by turning the furnace switch off and back on

When to call a technician

Repeated flame loss is a burner, flame sensor, gas pressure, or venting problem. Have a technician diagnose it rather than resetting repeatedly.

Sources

Trane furnace code E2.3: The control commanded the first-stage gas valve on and the valve did not energize, ten times in a row

Hard lockout

The control commanded the first-stage gas valve on and the valve did not energize, ten times in a row.

Manual wording: “1st Stage Gas Valve Not Energized When It Should Be exceeded after 10 times”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces with the seven-segment IFC display

Likely causes, most common first

  1. First stage gas valve not energized when it should be
  2. Gas valve or gas valve wiring fault
  3. Control board output fault

When to call a technician

This is a gas valve or control board fault. Call a technician; never work on a gas valve or its wiring yourself.

Sources

Trane furnace code E3.1: The first-stage pressure switch is reading closed when the control expects it to be open, which the control calls a shorted pressure switch

Soft lockout

The first-stage pressure switch is reading closed when the control expects it to be open, which the control calls a shorted pressure switch.

Manual wording: “Shorted Pressure Switch, 1st Stage”

Documented for: S8V2, S9V2 and S9V2-VS furnaces; on single-stage S8B1 the same code reads simply 'Shorted Pressure Switch'

Likely causes, most common first

  1. Shorted pressure switch, 1st stage
  2. Pressure switch contacts stuck closed
  3. Wiring fault across the pressure switch

When to call a technician

A stuck pressure switch is a safety-proving device. It must be tested and replaced by a technician, never jumpered.

Sources

Trane furnace code E3.2: The first-stage pressure switch will not close, so the control cannot prove the draft inducer is moving flue gas and will not open the gas valve

Soft lockout

The first-stage pressure switch will not close, so the control cannot prove the draft inducer is moving flue gas and will not open the gas valve.

Manual wording: “Open Pressure Switch, 1st Stage”

Documented for: S8V2, S9V2 and S9V2-VS furnaces; on single-stage S8B1 the same code reads simply 'Open Pressure Switch'

Likely causes, most common first

  1. Open pressure switch, 1st stage
  2. Blocked or restricted vent or combustion air piping
  3. Condensate backing up in the drain or trap (condensing models)
  4. Draft inducer not running or running weak
  5. Pressure switch tubing disconnected or plugged

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice, leaves, or nests
  • Check the condensate drain line and trap for a clog, and check that any condensate pump is working
  • Check that the furnace blower door is fully closed

When to call a technician

If the vents and drain are clear, the pressure switch, its tubing, or the inducer needs a technician. Do not jumper the pressure switch.

Sources

Trane furnace code E3.3: The second-stage pressure switch is reading closed when the control expects it to be open

Soft lockout

The second-stage pressure switch is reading closed when the control expects it to be open.

Manual wording: “Shorted Pressure Switch, 2nd Stage”

Documented for: Two-stage S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Shorted pressure switch, 2nd stage
  2. Second-stage pressure switch contacts stuck closed

When to call a technician

Pressure switch faults are a technician's job. The switch proves safe venting and must never be bypassed.

Sources

Trane furnace code E3.4: The second-stage pressure switch will not close, so the furnace cannot go to high fire

Soft lockout

The second-stage pressure switch will not close, so the furnace cannot go to high fire.

Manual wording: “Open Pressure Switch, 2nd Stage”

Documented for: Two-stage S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Open pressure switch, 2nd stage
  2. Restricted or blocked venting
  3. Draft inducer not reaching high-stage speed
  4. Pressure switch tubing problem

What you can safely check yourself

  • Check the outdoor intake and exhaust terminations for blockage
  • Check the condensate drain and trap for a clog (condensing models)

When to call a technician

If the venting is clear, the second-stage pressure switch or inducer needs a technician.

Sources

Trane furnace code E04: A safety limit has opened: the main thermal limit, a flame rollout switch, or the reverse airflow switch

Safety fault

A safety limit has opened: the main thermal limit, a flame rollout switch, or the reverse airflow switch. The furnace has stopped heating.

Manual wording: “Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch)”

Documented for: S8B1, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Open limit (main thermal, rollout switch, or reverse airflow switch)
  2. Restricted airflow across the heat exchanger from a dirty filter or blocked returns
  3. Blocked vent or combustion air terminations
  4. Flame rollout, which indicates a blocked heat exchanger or burner problem

What you can safely check yourself

  • Check the air filter and clean or replace it if dirty
  • Check that supply registers and return grilles are open and unblocked
  • Check the outdoor intake and exhaust terminations for snow, ice, or debris

When to call a technician

If the code returns after a clean filter and open vents, call a technician. A tripped rollout switch in particular means combustion gases came out of the burner box, which must be diagnosed before the furnace is run again. Never reset or bypass a rollout or limit switch yourself.

Sources

Trane furnace code E4.0: The high limit switch has opened because the furnace overheated

Soft lockout

The high limit switch has opened because the furnace overheated. This is the newer control's more specific version of E04.

Manual wording: “Open high limit switch”

Documented for: S8V2 two-stage induced draft furnaces (FNR-SVX003A control revision)

Likely causes, most common first

  1. Open high limit switch
  2. Restricted airflow from a dirty filter or blocked returns
  3. Blower not running or running slow

What you can safely check yourself

  • Check the air filter and clean or replace it if dirty
  • Check that supply registers and return grilles are open and unblocked
  • Make sure nothing is blocking the return air path to the furnace

When to call a technician

If the limit keeps opening with a clean filter and open vents, a technician needs to find why the furnace is overheating. Do not bypass the limit.

Sources

Trane furnace code E4.1: The reverse air-flow limit switch has opened, meaning air is moving through the furnace the wrong way or a downflow/horizontal airflow fault has been sensed

Safety fault

The reverse air-flow limit switch has opened, meaning air is moving through the furnace the wrong way or a downflow/horizontal airflow fault has been sensed.

Manual wording: “Open reverse air-flow limit switch”

Documented for: S8V2 two-stage induced draft furnaces (FNR-SVX003A control revision)

Likely causes, most common first

  1. Open reverse air-flow limit switch
  2. Blower rotating backwards or wired incorrectly
  3. Airflow problem specific to the furnace's installed orientation

What you can safely check yourself

  • Check that the furnace blower door is fully closed and latched
  • Check the air filter and replace it if dirty

When to call a technician

Call a technician. A reverse airflow trip means combustion products could be pushed the wrong way and it needs to be diagnosed before the furnace runs again.

Source

Trane furnace code E4.2: The flame roll-out limit switch has opened

Safety fault

The flame roll-out limit switch has opened. Flame or hot combustion gas came out of the burner box instead of going up the heat exchanger, and the switch shut off all gas flow.

Manual wording: “Open roll-out limit switch”

Documented for: S8V2 two-stage induced draft furnaces (FNR-SVX003A control revision)

Likely causes, most common first

  1. Open roll-out limit switch
  2. Blocked or cracked heat exchanger
  3. Blocked vent or restricted combustion air
  4. Burner or gas pressure problem

What you can safely check yourself

  • Turn the furnace switch off and leave it off
  • If you smell gas or see soot, leave the house and call the gas utility from outside

When to call a technician

Call a technician immediately and do not run the furnace. The manual describes the roll-out device as a thermal control that opens the circuit to shut off all flow of gas; the manual-reset roll-out limit must be reset by a qualified servicer only after the cause is found.

Source

Trane furnace code E05: The control is sensing a flame when there should not be one - for example with the gas valve commanded off

Safety fault

The control is sensing a flame when there should not be one - for example with the gas valve commanded off.

Manual wording: “Flame detected, should not be present”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Flame detected, should not be present
  2. Gas valve leaking through or slow to close
  3. Flame sensing circuit fault

What you can safely check yourself

  • Turn the furnace switch off and leave it off
  • If you smell gas, leave the house and call the gas utility from outside

When to call a technician

Call a technician. A flame signal with the valve off points at the gas valve and is a safety issue.

Sources

Trane furnace code E06: Line voltage polarity is reversed at the furnace, or the furnace is not properly grounded

Warning

Line voltage polarity is reversed at the furnace, or the furnace is not properly grounded.

Manual wording: “Voltage reversed polarity or Bad Grounding”

Documented for: S9V2-VS furnaces (FNR-SVX001B control revision)

Likely causes, most common first

  1. Voltage reversed polarity
  2. Bad grounding

What you can safely check yourself

  • Note whether the code appeared after electrical work or after the furnace was run on a generator

When to call a technician

Call a technician or electrician to correct line polarity and grounding at the furnace.

Source

Trane furnace code E6.1: Line and neutral are reversed in the 115 volt supply to the furnace

Warning

Line and neutral are reversed in the 115 volt supply to the furnace.

Manual wording: “Voltage reversed polarity”

Documented for: S8B1, S8V2 and S9V2 furnaces

Likely causes, most common first

  1. Voltage reversed polarity

What you can safely check yourself

  • Note whether the code appeared right after electrical work or a new circuit was run

When to call a technician

Call a technician or electrician to correct polarity at the furnace circuit.

Sources

Trane furnace code E6.2: The furnace does not have a good electrical ground, which the control needs in order to sense flame reliably

Warning

The furnace does not have a good electrical ground, which the control needs in order to sense flame reliably.

Manual wording: “Bad grounding”

Documented for: S8B1, S8V2 and S9V2 furnaces

Likely causes, most common first

  1. Bad grounding

When to call a technician

Call a technician or electrician. Correcting the ground path is electrical work inside the furnace.

Sources

Trane furnace code E6.3: Igniter fault

Hard lockout

Igniter fault. Either the igniter relay on the control has failed or the igniter itself is open (burned out).

Manual wording: “(1) Igniter relay fails (2) Igniter open”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Igniter relay fails
  2. Igniter open

What you can safely check yourself

  • Turn the furnace switch off and back on once to see whether the furnace attempts to light

When to call a technician

Call a technician. A hot surface igniter is fragile and lives in the burner compartment; replacing it or the control board is not a homeowner job.

Sources

Trane furnace code E7.1: The first-stage gas valve is energized when the control has commanded it off

Safety fault

The first-stage gas valve is energized when the control has commanded it off.

Manual wording: “1st stage gas valve (MVL) is energized when it should be off”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. 1st stage gas valve (MVL) is energized when it should be off
  2. Gas valve relay stuck closed on the control board

What you can safely check yourself

  • Turn the furnace switch off and leave it off until a technician has looked at it

When to call a technician

Call a technician. A gas valve energized without a command is a safety fault involving the gas valve circuit.

Sources

Trane furnace code E7.2: The redundant safety relay on the control

Safety fault

The redundant safety relay on the control (HLO output) is energized when it should not be.

Manual wording: “Redundant Relay (HLO output) Energized when it should NOT be”

Documented for: S8V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Redundant relay (HLO output) energized when it should NOT be
  2. Control board relay fault

When to call a technician

Call a technician. The redundant relay is part of the gas-valve safety chain and a stuck relay means the board must be replaced.

Sources

Trane furnace code E08: The flame current the control reads is low but still high enough to keep running

Warning

The flame current the control reads is low but still high enough to keep running. This is an early warning, not a shutdown.

Manual wording: “Flame current is low, but still strong enough to allow operation”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Flame current is low, but still strong enough to allow operation
  2. Dirty or degraded flame sensor
  3. Weak or poorly positioned burner flame
  4. Marginal grounding

What you can safely check yourself

  • Note that the furnace is likely still heating; schedule service rather than treating it as an emergency

When to call a technician

Schedule service before it turns into an ignition lockout. Cleaning or repositioning a flame sensor means opening the burner compartment, which is a technician's job.

Sources

Trane furnace code E09: The inducer limit switch or the condensate pressure switch is open

Soft lockout

The inducer limit switch or the condensate pressure switch is open. On a condensing furnace this most often means condensate is backing up.

Manual wording: “Open Inducer Limit Switch or Condensate Pressure Switch”

Documented for: S9V2 and S9V2-VS condensing furnaces

Likely causes, most common first

  1. Open inducer limit switch or condensate pressure switch
  2. Blocked condensate drain, trap, or hose
  3. Frozen condensate in an outdoor-run drain line
  4. Full or failed condensate pump
  5. Inducer overheating

What you can safely check yourself

  • Check the condensate drain line and trap for a clog and clear standing water from the drain pan area if you can reach it safely
  • Check that any condensate pump is plugged in, not full, and pumping
  • In freezing weather, check whether any part of the drain line runs somewhere cold enough to freeze

When to call a technician

If the drain and pump are clear, the inducer limit or condensate switch needs a technician. Do not bypass either switch.

Sources

Trane furnace code E10: The control is not getting a response from the variable-speed inducer motor, or the two microcontrollers on the board cannot talk to each other

Hard lockout

The control is not getting a response from the variable-speed inducer motor, or the two microcontrollers on the board cannot talk to each other.

Manual wording: “Inducer Motor no communication response, could be communication failure between two micro-controllers.”

Documented for: S9V2-VS furnaces with variable-speed draft inducer

Likely causes, most common first

  1. Inducer motor no communication response
  2. Communication failure between two micro-controllers
  3. Loose inducer motor harness

What you can safely check yourself

  • Turn the furnace switch off and back on once to see whether the code clears

When to call a technician

Call a technician. Diagnosing the inducer motor's communication link means working in the live control compartment.

Source

Trane furnace code E11: Gas valve relay fault

Safety fault

Gas valve relay fault. The control has found one of the gas valve outputs or relays in the wrong state - either energized without a command or not energizing when commanded.

Manual wording: “(1) 1st stage gas valve not energized when it should be (2) 1st stage gas valve relay stuck closed (3) 2nd stage gas valve relay stuck closed (4) 2nd stage gas valve energized when it should not be (5) 2nd stage gas valve not energized when it should be”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. 1st stage gas valve not energized when it should be
  2. 1st stage gas valve relay stuck closed
  3. 2nd stage gas valve relay stuck closed
  4. 2nd stage gas valve energized when it should not be
  5. 2nd stage gas valve not energized when it should be

What you can safely check yourself

  • Turn the furnace switch off and leave it off until a technician has looked at it

When to call a technician

Call a technician. A stuck gas valve relay is a safety fault and normally means replacing the integrated furnace control.

Sources

Trane furnace code E12: The 5 amp fuse on the integrated furnace control has opened, so 24 volt control power is lost

Hard lockout

The 5 amp fuse on the integrated furnace control has opened, so 24 volt control power is lost.

Manual wording: “Open fuse”

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Open fuse
  2. Short in the low-voltage thermostat or accessory wiring
  3. Short in a control circuit component

What you can safely check yourself

  • Note whether the code appeared right after a thermostat was replaced or new low-voltage wiring was run, and mention that to the technician

When to call a technician

Call a technician. The fuse blew because something shorted; replacing it without finding the short will just blow it again.

Sources

Trane furnace code E13: The blower motor's horsepower or OEM ID does not match what the furnace's personality module expects

Hard lockout

The blower motor's horsepower or OEM ID does not match what the furnace's personality module expects.

Manual wording: “Blower HP or OEM ID do not match furnace”

Documented for: S8V2, S9V2 and S9V2-VS furnaces with ECM blower motors

Likely causes, most common first

  1. Blower HP or OEM ID do not match furnace
  2. Wrong replacement blower motor installed
  3. Wrong or missing personality module

What you can safely check yourself

  • Mention to the technician whether the blower motor or control board was recently replaced

When to call a technician

Call a technician. This is a parts-matching problem between the blower motor, the control, and the furnace's personality module.

Sources

Trane furnace code E17: The control is not getting a response from the ECM blower motor, so the indoor blower will not run

Hard lockout

The control is not getting a response from the ECM blower motor, so the indoor blower will not run.

Manual wording: “Blower motor no communication response”

Documented for: S8V2, S9V2 and S9V2-VS furnaces with ECM blower motors

Likely causes, most common first

  1. Blower motor no communication response
  2. Loose or damaged motor communication harness
  3. Failed blower motor control module

What you can safely check yourself

  • Turn the furnace switch off and back on once to see whether the blower starts
  • Make sure the blower door is fully closed and latched

When to call a technician

Call a technician. The blower motor and its communication harness are inside the blower compartment and diagnosing them requires live testing.

Sources

How old is this Trane?

Age changes what a fault code means for you. The same failure is a routine repair on a six-year-old unit and the end of the line on a twenty-year-old one. Your Trane serial number has the build date in it.

Decode your Traneserial number →