Amana Furnace Code 4
WarningShown as: 4 flashes, then a pause, repeating
Open limit switch. The furnace overheated and the high limit (or auxiliary limit) tripped. The blower keeps running to cool the heat exchanger. This is almost always an airflow problem.
Manual wording: “Open Main or Auxillary Temperature Limit Switch”
Documented for: Amana AMS8, AMH8, ADS8, ADH8, AMEH8, AMES80, ACES80, AMSS92, AMSS96, ACSS96 (single red diagnostic LED)
Likely causes, most common first
- Insufficient conditioned air over the heat exchanger
- Blocked filters
- Restrictive ductwork
- Improper circulator blower speed or a failed circulator blower
- Faulty primary or auxiliary limit switch
- Loose or improperly connected wiring
What you can safely check yourself
- Check the air filter and replace it if it is dirty - this is the number one cause of a 4-flash code
- Open all supply registers and make sure furniture, rugs or boxes are not blocking them
- Make sure the return air grille is not blocked or covered
- Check that any humidifier bypass damper is set correctly for the season
When to call a technician
If the code returns after a clean filter and open registers, the limit is tripping for a reason a technician must find - a failing blower, a restricted duct system, or a cracked heat exchanger. Never jumper or bypass a limit switch.
A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation Instructions for *M(H,S)8 / GD(H,S)8 / GHS8 / GME8 / ADS(H,S)8 / AMEH8 / VMS8 / VDS8 Gas Furnace (Category I) - IO-446F (Daikin Comfort Technologies (Amana brand), Amana AMS8, AMH8, ADS8, ADH8, AMEH8 80% AFUE gas furnaces (PCBBF132 / PCBBF134 control boards)) · checked 2026-08-25
- Installation Instructions - *MES80 / *CES80 Gas Furnace, Category I - IOG-2021H (Daikin Comfort Technologies (Amana brand), Amana AMES80, ACES80 80% AFUE gas furnaces (PCBBF145 control board)) · checked 2026-08-25
- Installation Instructions for *MSS9* & *CSS9* Single-Stage Gas Furnace - IOG-2009Q (Daikin Comfort Technologies (Amana brand), Amana AMSS92, AMSS96, ACSS96 single-stage 92/96% AFUE gas furnaces) · checked 2026-08-25