HVAC Code Lookup

Amana Furnace Code 8

Hard lockoutShown as: 8 flashes, then a pause, repeating

Igniter relay fault. The control board detected a problem with the relay that powers the hot surface igniter, so the furnace will not run.

Manual wording: “Igniter Relay Fault

Documented for: Amana AMES80, ACES80, AMSS92, AMSS96, ACSS96

Likely causes, most common first

  1. Improperly connected igniter
  2. Bad igniter
  3. Poor unit ground
  4. Poor burner ground
  5. Faulty integrated control module

What you can safely check yourself

  • Turn the furnace off at its power switch for about 30 seconds and back on once to see if the code clears

When to call a technician

Igniter, ground wiring and control board diagnosis are technician work.

A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.