HVAC Code Lookup

Amana Furnace Code EEH

Soft lockout

Twinning error. Two furnaces are set up to run as a pair and the controls cannot communicate, so the blowers will not run together.

Manual wording: “Error with Twinning function.

Documented for: Amana AMVC96, ACVC96, AMVM97, ACVM97, AM9S80, AC9S80, AR9S80, AD9S80, AR9T96, AD9T96 (seven-segment display controls)

Likely causes, most common first

  1. Both furnaces not on the same 120VAC power from the breaker panel
  2. Low voltage wiring error or loose wiring connections
  3. Damaged twinning wire between the two control boards

When to call a technician

Twinned furnace wiring is an installer configuration. Call the contractor who installed the pair.

A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Amana codes