HVAC Code Lookup

Amana Furnace Code 10

Hard lockoutShown as: 10 flashes, then a pause, repeating

Open fuse. The 3 amp fuse on the control board has blown, so there is no 24 volt power to the control and the furnace will not run.

Manual wording: “Open Fuse / No 24V power to integrated control module

Documented for: Amana AMES80, ACES80 (PCBBF145 control board)

Likely causes, most common first

  1. High voltage surge blows off the fuse
  2. Short in the 24 volt low-voltage wiring

What you can safely check yourself

  • Check that the furnace breaker in the electrical panel has not tripped, and reset it once if it has

When to call a technician

Replacing the control board fuse without finding the short that blew it just blows the next fuse. Have a technician find the fault.

A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.