HVAC Code Lookup

Payne Furnace Code 45

Soft lockoutShown as: 4 short flashes, 5 long flashes

Control circuitry lockout. The board detected an internal failure and locks out, auto-resetting after 1 hour.

Manual wording: “45 CONTROL CIRCUITRY LOCKOUT Auto-reset after 1 hour lockout due to: - Flame circuit failure. - Gas valve relay stuck open. - Software check error.

Documented for: PG92ESA, PG95ESA, PG96VTA

Likely causes, most common first

  1. Flame circuit failure
  2. Gas valve relay stuck open
  3. Software check error

What you can safely check yourself

  • Turn the furnace off at the service switch for a minute and back on once - the manual says resetting power clears the lockout

When to call a technician

Payne's own instruction is to replace the control if the code repeats after a power reset. That is a technician job.

A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Payne codes