Safety faultShown as: Major code 14 flashed on the LED (1 short, 4 long); 14.2 on the display

Flame lost lockout - the flame signal was lost three times after the heating blower on-delay. Auto-resets after 3 hours.

Manual wording: “14.2 FLAME LOST LOCKOUT - Flame signal was lost 3 times after heating blower on delay. Control will auto-reset after 3 hours. See status code 34.3.

Documented for: PG80MSU

Likely causes, most common first

  1. Incorrect manifold pressure and gas firing rate
  2. Gas inlet pressure fluctuations
  3. Improper pressure transducer operation
  4. Flame sensing problem - see code 34

What you can safely check yourself

  • Check that the air filter is clean and vents are open

When to call a technician

Repeated loss of an established flame is a combustion fault. Have a technician verify gas pressure and flame sensing before running the furnace.

A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.