Payne Furnace Code 34.3
Safety faultShown as: Major code 34 on the LED (3 short, 4 long); 34.3 on the display
Flame lost - after successful ignition (flame proven), flame was lost after the heating blower on-delay.
Manual wording: “34.3 FLAME LOST - After successful ignition (flame proven) flame lost after heating blower on delay.”
Documented for: PG80MSU
Likely causes, most common first
- Oxide buildup on the flame sensor
- Low inlet gas pressure
- Poor control ground continuity
- Airflow disturbing the flame
What you can safely check yourself
- Check that the air filter is clean and supply and return vents are open
When to call a technician
Losing flame once the blower starts usually points at gas pressure or flame sensing - have a technician measure flame current and manifold pressure.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG80MSU 80% multipoise gas furnace with 3-digit display and pressure transducer) · checked 2026-08-25