HVAC Code Lookup

Payne Furnace Code 31.5

WarningShown as: Major code 31 on the LED (3 short, 1 long); 31.5 on the display

Loss of pressure after the blower comes on. The pressure transducer does not sense the target pressure, or pressure is out of range for the operating stage.

Manual wording: “31.5 LOSS OF PRESSURE - After blower comes on.

Documented for: PG80MSU

Likely causes, most common first

  1. Improper vent sizing
  2. Low inducer voltage (115 V)
  3. Inadequate combustion air supply
  4. Disconnected or obstructed pressure tubing
  5. Defective inducer motor
  6. Defective pressure transducer
  7. Excessive wind
  8. Restricted vent system

What you can safely check yourself

  • Check outdoor vent terminations for blockage
  • Replace a dirty air filter

When to call a technician

Losing vent pressure once the blower starts often points at vent sizing or a failing inducer - have a technician measure it.

A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Payne codes