Payne Furnace: 1 Flashes
A Payne furnace LED pattern starting with 1 flashes matches 7 documented codes: 10.1, 11, 12, 13, 14, 14.2, 14.3. Watch the full pattern (short vs. long flashes) to tell them apart — all 7 are explained below.
Code 10.1: L1 polarity fault - the polarity of the incoming 115 V power is reversed
L1 polarity fault - the polarity of the incoming 115 V power is reversed.
Manual wording: “10.1 L1 POLARITY FAULT - Rapid flash LED. Polarity of incoming 115V power is reversed.”
Documented for: PG80MSU
Likely causes, most common first
- Line voltage (115 V) hot and neutral reversed at a junction
- Improper low-voltage (24 V) transformer phasing on twinned units
When to call a technician
Fixing 115 V polarity requires opening junction boxes on live wiring - call a licensed technician or electrician.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG80MSU 80% multipoise gas furnace with 3-digit display and pressure transducer) · checked 2026-08-25
Code 11: No previous code
No previous code. Nothing is stored in the control's fault memory; stored codes erase automatically after 72 hours.
Manual wording: “11 NO PREVIOUS CODE - Stored codes are erased after 72 hours. Run system through a heating or cooling cycle to check system.”
Documented for: PG92ESA, PG95ESA, PG96VTA
Likely causes, most common first
- Normal - no stored fault
- A previous fault aged out after 72 hours or was manually cleared
What you can safely check yourself
- Nothing to fix - run the furnace through a full heating cycle and see whether a real code appears
When to call a technician
If the furnace misbehaves but only shows 11, a technician should watch a live cycle to catch the fault as it happens.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- PG92ESA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG92ESA multipoise 92% single-stage condensing gas furnace) · checked 2026-08-25
- PG95ESA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG95ESA multipoise 95% single-stage condensing gas furnace) · checked 2026-08-25
- PG96VTA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG96VTA two-stage, variable-speed ECM 4-way multipoise condensing gas furnace) · checked 2026-08-25
Code 12: Blower on after power up - normal operation
Blower on after power up - normal operation. The blower runs for 90 seconds because power was restored during a call for heat, or the call ended during the blower on-delay.
Manual wording: “12 BLOWER ON AFTER POWER UP - (115V OR 24V) - Normal operation. Blower runs for 90 seconds, if unit is powered up during a call for heat (R-W closed)”
Documented for: PG92ESA, PG95ESA, PG96VTA, PG80MSU
Likely causes, most common first
- Power was interrupted and restored during a call for heat
- Thermostat call ended during the blower on-delay period
What you can safely check yourself
- Nothing to fix - this is normal after a power blip or after switching the furnace back on
When to call a technician
If code 12 keeps appearing without any power outages, have a technician check for a loose 115 V connection or a failing door switch.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- PG92ESA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG92ESA multipoise 92% single-stage condensing gas furnace) · checked 2026-08-25
- PG95ESA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG95ESA multipoise 95% single-stage condensing gas furnace) · checked 2026-08-25
- PG96VTA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG96VTA two-stage, variable-speed ECM 4-way multipoise condensing gas furnace) · checked 2026-08-25
- PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG80MSU 80% multipoise gas furnace with 3-digit display and pressure transducer) · checked 2026-08-25
Code 13: Limit circuit lockout
Limit circuit lockout. The limit or flame rollout switch has been open longer than 3 minutes. The control locks out and auto-resets after 3 hours.
Manual wording: “13 LIMIT CIRCUIT LOCKOUT - Lockout occurs if the limit or flame rollout is open longer than 3 minutes. Control will auto-reset after 3 hours. See code 33.”
Documented for: PG92ESA, PG95ESA, PG96VTA, PG80MSU
Likely causes, most common first
- Restricted vent or improper vent sizing
- Dirty filter or restricted duct system
- Blower motor not functioning
- Defective switch or connections
- Inadequate combustion air supply
What you can safely check yourself
- Check and replace a dirty air filter
- Make sure supply registers and return grilles are open and unblocked
- Make sure the furnace blower door is fully closed
When to call a technician
A 3-minute limit trip means the furnace was really overheating or not venting. Have a technician confirm why before running it again; a tripped flame rollout switch must never be reset without finding the cause.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- PG92ESA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG92ESA multipoise 92% single-stage condensing gas furnace) · checked 2026-08-25
- PG95ESA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG95ESA multipoise 95% single-stage condensing gas furnace) · checked 2026-08-25
- PG96VTA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG96VTA two-stage, variable-speed ECM 4-way multipoise condensing gas furnace) · checked 2026-08-25
- PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG80MSU 80% multipoise gas furnace with 3-digit display and pressure transducer) · checked 2026-08-25
Code 14: Ignition lockout
Ignition lockout. The furnace failed to ignite the gas and prove flame in four attempts. The control auto-resets after 3 hours.
Manual wording: “14 IGNITION LOCKOUT - System failed to ignite gas and prove flame in 4 attempts. Control will auto-reset after 3 hours. See status code 34.”
Documented for: PG92ESA, PG95ESA, PG96VTA, PG80MSU
Likely causes, most common first
- Igniter, flame sensor, or gas valve problem - see code 34
- Low inlet gas pressure or a closed manual gas valve
- Loss of control ground continuity
What you can safely check yourself
- Confirm other gas appliances in the house work, so you know gas service is on
- Turn the furnace off at the service switch for a minute and back on once for one clean retry
When to call a technician
Ignition faults are inside the burner compartment of a live gas appliance. Have a technician check the igniter, flame sensor, gas valve, and gas pressure.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- PG92ESA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG92ESA multipoise 92% single-stage condensing gas furnace) · checked 2026-08-25
- PG95ESA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG95ESA multipoise 95% single-stage condensing gas furnace) · checked 2026-08-25
- PG96VTA: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG96VTA two-stage, variable-speed ECM 4-way multipoise condensing gas furnace) · checked 2026-08-25
- PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG80MSU 80% multipoise gas furnace with 3-digit display and pressure transducer) · checked 2026-08-25
Code 14.2: Flame lost lockout - the flame signal was lost three times after the heating blower on-delay
Flame lost lockout - the flame signal was lost three times after the heating blower on-delay. Auto-resets after 3 hours.
Manual wording: “14.2 FLAME LOST LOCKOUT - Flame signal was lost 3 times after heating blower on delay. Control will auto-reset after 3 hours. See status code 34.3.”
Documented for: PG80MSU
Likely causes, most common first
- Incorrect manifold pressure and gas firing rate
- Gas inlet pressure fluctuations
- Improper pressure transducer operation
- Flame sensing problem - see code 34
What you can safely check yourself
- Check that the air filter is clean and vents are open
When to call a technician
Repeated loss of an established flame is a combustion fault. Have a technician verify gas pressure and flame sensing before running the furnace.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG80MSU 80% multipoise gas furnace with 3-digit display and pressure transducer) · checked 2026-08-25
Code 14.3: Flame lost lockout - the flame signal was lost seven times during a single heat request
Flame lost lockout - the flame signal was lost seven times during a single heat request.
Manual wording: “14.3 FLAME LOST LOCKOUT - Flame signal was lost 7 times during a single heat request. See status code 34.2 to 34.4.”
Documented for: PG80MSU
Likely causes, most common first
- Incorrect manifold pressure and gas firing rate
- Gas inlet pressure fluctuations
- Improper pressure transducer operation
What you can safely check yourself
- Check that the air filter is clean and supply and return vents are open
When to call a technician
Do not keep resetting the furnace. Seven flame losses in one heat call needs a technician to check gas supply and the combustion setup.
A Payne furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions (Payne, PG80MSU 80% multipoise gas furnace with 3-digit display and pressure transducer) · checked 2026-08-25