Carrier Furnace: 2 Flashes
A Carrier furnace LED pattern starting with 2 flashes matches 5 documented codes: 21, 22, 23, 24, 25. Watch the full pattern (short vs. long flashes) to tell them apart — all 5 are explained below.
Code 21: Gas heating lockout
Gas heating lockout. The control detected 24 VAC on the gas valve when it should not be there. This lockout does NOT auto-reset.
Manual wording: “21 GAS HEATING LOCKOUT - Control will NOT auto reset. Check for: - Mis-wired gas valve. - Defective control (valve relay).”
Documented for: 58SC0A, 58MCB, 58MVP, 58UVB
Likely causes, most common first
- Stuck-closed gas valve relay on the control board
- Mis-wired or shorted gas valve wire
When to call a technician
Code 21 means the control can no longer guarantee it can shut the gas valve off. Shut the furnace off at the service switch and call a technician - this one does not clear on its own.
A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Troubleshooting Guide - Variable Speed, Two-Stage Gas Furnaces (Form 58-06T) (Carrier, 58MVP, 58UVB and other Carrier variable-speed two-stage gas furnaces (replaces 58MVP-10SM)) · checked 2026-08-25
- Installation, Start-Up, Operating and Service and Maintenance Instructions - 58SC0A/58SC1A (Carrier, 58SC0A/58SC1A single-stage 4-way multipoise condensing gas furnace) · checked 2026-08-25
- 58MCB 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace - Service Manual (Carrier, 58MCB single-stage condensing gas furnace) · checked 2026-08-25
Code 22: Abnormal flame-proving signal
Abnormal flame-proving signal (false flame). The control senses flame while the gas valve is de-energized. The inducer will keep running until the fault clears.
Manual wording: “22 ABNORMAL FLAME-PROVING SIGNAL - Flame is proved while gas valve is de-energized. Inducer will run until fault is cleared.”
Documented for: 58SC0A, 58MCB, 58MVP, 58UVB
Likely causes, most common first
- Leaky gas valve
- Stuck-open gas valve
When to call a technician
This code means gas may be burning when the control has commanded the valve closed. Turn the furnace off at the service switch and call a technician immediately. Do not touch or attempt to test the gas valve.
A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Troubleshooting Guide - Variable Speed, Two-Stage Gas Furnaces (Form 58-06T) (Carrier, 58MVP, 58UVB and other Carrier variable-speed two-stage gas furnaces (replaces 58MVP-10SM)) · checked 2026-08-25
- 58MCB 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace - Service Manual (Carrier, 58MCB single-stage condensing gas furnace) · checked 2026-08-25
- Installation, Start-Up, Operating and Service and Maintenance Instructions - 58SC0A/58SC1A (Carrier, 58SC0A/58SC1A single-stage 4-way multipoise condensing gas furnace) · checked 2026-08-25
Code 23: Pressure switch did not open
Pressure switch did not open. The control expected the vent pressure switch to be open at the start of the cycle and it was still closed.
Manual wording: “23 PRESSURE SWITCH DID NOT OPEN - Check for: - Obstructed pressure tubing. - Pressure switch stuck closed.”
Documented for: 58SC0A, 58MCB, 58MVP, 58UVB
Likely causes, most common first
- Obstructed pressure tubing
- Pressure switch stuck closed
When to call a technician
The pressure switch is a combustion safety device. A technician needs to inspect the tubing and switch - never bypass or jumper a pressure switch.
A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Troubleshooting Guide - Variable Speed, Two-Stage Gas Furnaces (Form 58-06T) (Carrier, 58MVP, 58UVB and other Carrier variable-speed two-stage gas furnaces (replaces 58MVP-10SM)) · checked 2026-08-25
- Installation, Start-Up, Operating and Service and Maintenance Instructions - 58SC0A/58SC1A (Carrier, 58SC0A/58SC1A single-stage 4-way multipoise condensing gas furnace) · checked 2026-08-25
- 58MCB 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace - Service Manual (Carrier, 58MCB single-stage condensing gas furnace) · checked 2026-08-25
Code 24: The 3-amp secondary voltage fuse on the control board is blown, which means there is a short somewhere in the 24 V low-voltage wiring
The 3-amp secondary voltage fuse on the control board is blown, which means there is a short somewhere in the 24 V low-voltage wiring.
Manual wording: “24 SECONDARY VOLTAGE FUSE IS OPEN - Check for: - Short circuit in secondary voltage (24V) wiring including thermostat leads.”
Documented for: 58SC0A, 58MCB, 58MVP, 58UVB
Likely causes, most common first
- Short circuit in the 24 VAC secondary wiring, including the thermostat leads
When to call a technician
Replacing the fuse without finding the short just blows the new fuse. A technician needs to isolate the shorted thermostat or accessory wire.
A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation, Start-Up, Operating and Service and Maintenance Instructions - 58SC0A/58SC1A (Carrier, 58SC0A/58SC1A single-stage 4-way multipoise condensing gas furnace) · checked 2026-08-25
- Troubleshooting Guide - Variable Speed, Two-Stage Gas Furnaces (Form 58-06T) (Carrier, 58MVP, 58UVB and other Carrier variable-speed two-stage gas furnaces (replaces 58MVP-10SM)) · checked 2026-08-25
- 58MCB 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace - Service Manual (Carrier, 58MCB single-stage condensing gas furnace) · checked 2026-08-25
Code 25: Model selection or setup error
Model selection or setup error. The model plug (PL4) is missing or wrong, or a setup switch is in the wrong position. If the code flashes only 4 times at power-up, the control is running on the model selection stored in memory.
Manual wording: “25 MODEL SELECTION OR SETUP ERROR - Either Indicates the model plug (PL4) is missing or incorrect or setup switch "SW1-1" or "SW1-6" is positioned improperly.”
Documented for: 58MVP, 58UVB and other variable-speed two-stage Carrier furnaces
Likely causes, most common first
- Model plug PL4 missing or incorrect (common after a replacement control board)
- Setup switch SW1-1 or SW1-6 left ON
- Two different furnace models twinned together
When to call a technician
This is a setup fault that appears after service work. The technician who last worked on the furnace needs to install the correct model plug and reset the setup switches.
A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Troubleshooting Guide - Variable Speed, Two-Stage Gas Furnaces (Form 58-06T) (Carrier, 58MVP, 58UVB and other Carrier variable-speed two-stage gas furnaces (replaces 58MVP-10SM)) · checked 2026-08-25