Carrier Furnace Rapid Flash

Hard lockoutShown as: Very fast continuous flashing with no pause between flashes

Line voltage (115 VAC) polarity is reversed at the furnace. The control cannot prove flame with reversed polarity, so the furnace will not run.

Manual wording: “RAPID FLASHING - Line voltage (115VAC) polarity reversed. If twinned, refer to twinning kit instructions.

Documented for: 58MCB, 58MVP, 58UVB and most Carrier 58-series furnaces

Likely causes, most common first

  1. Hot and neutral swapped at a junction box, outlet, or the furnace itself
  2. On twinned furnaces, incorrect low-voltage (24 V) transformer phasing

When to call a technician

Reversed line-voltage polarity is an electrical wiring fault. A technician (or electrician) has to find and correct the crossed hot and neutral - this is not a homeowner repair.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.