Carrier Furnace Code 22
Safety faultShown as: 2 short flashes, 2 long flashes
Abnormal flame-proving signal (false flame). The control senses flame while the gas valve is de-energized. The inducer will keep running until the fault clears.
Manual wording: “22 ABNORMAL FLAME-PROVING SIGNAL - Flame is proved while gas valve is de-energized. Inducer will run until fault is cleared.”
Documented for: 58SC0A, 58MCB, 58MVP, 58UVB
Likely causes, most common first
- Leaky gas valve
- Stuck-open gas valve
When to call a technician
This code means gas may be burning when the control has commanded the valve closed. Turn the furnace off at the service switch and call a technician immediately. Do not touch or attempt to test the gas valve.
A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.