York Furnace 9 Red Flashes
Hard lockoutShown as: Nine red flashes, then a two-second pause, repeating
Reversed line voltage polarity, a grounding problem, or reversed low voltage transformer wires. The furnace will not start the ignition sequence until this is corrected, and both heating and cooling are affected.
Manual wording: “9 RED FLASHES: Indicates reversed line voltage polarity, grounding problem or reversed low voltage transformer wires. Both heating and cooling operations will be affected.”
Documented for: TG8S, TG9S, TM9E, TM9X, TM8X, TM9T, TM8T, TM9V, TM8Y, TM9Y
Likely causes, most common first
- Reversed line voltage polarity (hot and neutral swapped) at the furnace or at the branch circuit
- Poor or missing furnace ground
- Reversed low voltage transformer wires
- Flame probe shorted to the chassis
What you can safely check yourself
- If this appeared right after electrical work or a new outlet/breaker was installed, mention that to the technician
- Check the furnace breaker is fully on
When to call a technician
Polarity and grounding faults are line-voltage electrical work. Have a technician or electrician check the polarity and ground at the furnace and at the branch circuit.
A York furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation Manual - Single Stage PSC Residential Gas Furnaces, TG9S and GG9S Series (95.5% AFUE Multi-position), 1083287-UIM-A-0114 (Johnson Controls Unitary Products (York), TG9S*MP, GG9S*MP single-stage PSC 95.5% AFUE gas furnaces) · checked 2026-08-25
- Installation Manual - Single Stage PSC Residential Gas Furnaces, TG8S*MP / TGLS*MP / GG8S*MP / GGLS*MP (80% AFUE Multi-position / Standard Low NOx), 998491-UIM-B-1013 (Johnson Controls Unitary Products (York), TG8S*MP, TGLS*MP, GG8S*MP, GGLS*MP 80% AFUE single-stage gas furnaces) · checked 2026-08-25
- Installation Manual - Single Stage ECM Residential Gas Furnaces, TM9E Series (95% AFUE Multi-position), 1083163-UIM-A-0214 (Johnson Controls Unitary Products (York), TM9E*MP single-stage ECM 95% AFUE gas furnaces) · checked 2026-08-25
- Installation Manual - Two Stage Variable Speed ECM Residential Gas Furnaces, TM9V Series (96% AFUE Multi-position), 1083294-UIM-A-0114 (Johnson Controls Unitary Products (York), TM9V*MP two-stage variable-speed ECM 96% AFUE gas furnaces) · checked 2026-08-25