York Furnace Continuous Red Flash

WarningShown as: Red LED flashing on and off continuously with no pauses

Twinning error on the TM8Y / TM9Y (and TM8T / TM9T) boards: incorrect 24V phasing between two twinned furnaces, or no power to the twinned unit.

Manual wording: “CONTINUOUS RED FLASH: Twinning error, incorrect 24V phasing or no power to twinned unit. Check twinning wiring. Confirm that both twinned units have power.

Documented for: TM8Y, TM9Y (and the TM8T / TM9T two-stage PSC chassis)

Likely causes, most common first

  1. Incorrect 24V phasing between twinned furnaces
  2. No power to the twinned unit
  3. Twinning wiring error

What you can safely check yourself

  • Check the breaker and service switch for the second (twinned) furnace are on

When to call a technician

Have a technician verify the twinning wiring and 24V transformer phasing between the two furnaces.

A York furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.