HVAC Code Lookup

York Furnace Continuous Green Flash

WarningShown as: Green LED flashing on and off continuously with no pauses

Twinning error. Two furnaces are wired together on a common duct system and the 24V control power is out of phase, or one of the twinned units has lost power.

Manual wording: “CONTINUOUS GREEN FLASH: Twinning error, incorrect 24V phasing or no power to twinned unit. Check twinning wiring. Confirm that both twinned units have power.

Documented for: TG8S, TG9S and other twinnable UPG single-stage furnaces. On TM8Y / TM9Y the same twinning fault is shown as a continuous RED flash instead.

Likely causes, most common first

  1. Incorrect 24V phasing between twinned furnaces
  2. No power to the twinned unit
  3. Twinning wiring error

What you can safely check yourself

  • Check the breaker and service switch for the second (twinned) furnace are on

When to call a technician

Twinning phasing is a wiring job. A technician needs to verify the 24V transformer phasing and twinning harness between the two furnaces.

A York furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other York codes