York Furnace 5 Amber Flashes (YP9C Modulating)
WarningShown as: Five amber flashes, two-second pause, repeating
The furnace has cut back its heating output because the combustion air or vent system is restricted. Above 4,000 feet altitude this can also be normal automatic derating.
Manual wording: “Five Amber Flashes - Heating capacity is reduced due to restriction in the combustion air or vent system. Check for blocked vent/air pipe or clogged condensate drain.”
Documented for: YP9C, YPLC modulating furnaces
Likely causes, most common first
- Blocked vent or air intake pipe
- Clogged condensate drain
- Normal altitude derating above 4,000 feet
What you can safely check yourself
- Check the outside vent and intake pipe terminations for snow, ice, leaves or nests
- Check the condensate drain and trap for a clog
When to call a technician
If the pipes and drain are clear and you are not at high altitude, have a technician check the venting and inducer.
A York furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installation Manual - Modulating ECM Residential Gas Furnace with ECM Motor, Models YP9C*C / TP9C*C / CP9C*C / LP9C*C (Up to 98% Modulating Multi-position), 1083292-UIM-A-0114 (Johnson Controls Unitary Products (York), YP9C*C (York Affinity modulating), and the identical TP9C / CP9C / LP9C chassis) · checked 2026-08-25