HVAC Code Lookup

York Furnace 3 Red Flashes (YP9C Modulating)

Soft lockoutShown as: Three red flashes, two-second pause, repeating

The pressure switch is open while inducer pressure is above the switch setpoint - the switch is open when it should be closed, so the burners cannot light.

Manual wording: “Three Red Flashes - Pressure switch open with inducer pressure above pressure switch setpoint (switch is open when it should be closed). Check pressure switch and pressure transducer.

Documented for: YP9C, YPLC modulating furnaces

Likely causes, most common first

  1. Faulty pressure switch
  2. Faulty pressure transducer

What you can safely check yourself

  • Check the outside vent and intake pipe terminations for snow, ice, leaves or nests
  • Check the condensate drain and trap for a clog

When to call a technician

If the venting and drain are clear, the pressure switch or transducer needs a technician with a manometer.

A York furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other York codes