York Furnace: 6 Flashes
A York furnace LED pattern starting with 6 flashes matches 3 documented codes: 6 red flashes, 6 amber flashes (YP9C modulating), 6 red flashes (YP9C modulating). Watch the full pattern (short vs. long flashes) to tell them apart — all 3 are explained below.
Code 6 red flashes: While the furnace was running, the pressure switch opened four times during one call for heat
While the furnace was running, the pressure switch opened four times during one call for heat. The furnace locks out for one hour, then tries again on its own.
Manual wording: “6 RED FLASHES: This indicates that while the unit was operating, the pressure switch opened four times during the call for heat. Check for faulty inducer, blocked vent pipe or faulty pressure switch. The furnace will lock out for one hour and then restart.”
Documented for: TG8S, TG9S, TM9E, TM9X, TM8X, TM9T, TM8T, TM9V, TM8Y, TM9Y
Likely causes, most common first
- Faulty inducer (draft) motor
- Blocked vent pipe
- Faulty pressure switch
What you can safely check yourself
- Check the outside vent and intake pipe terminations for snow, ice, leaves or nests
- Check the condensate drain and trap for a clog
- Replace a dirty air filter
When to call a technician
If the pipes are clear and the furnace keeps dropping out, the inducer or pressure switch is failing and needs a technician.
A York furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation Manual - Single Stage PSC Residential Gas Furnaces, TG9S and GG9S Series (95.5% AFUE Multi-position), 1083287-UIM-A-0114 (Johnson Controls Unitary Products (York), TG9S*MP, GG9S*MP single-stage PSC 95.5% AFUE gas furnaces) · checked 2026-08-25
- Installation Manual - Single Stage PSC Residential Gas Furnaces, TG8S*MP / TGLS*MP / GG8S*MP / GGLS*MP (80% AFUE Multi-position / Standard Low NOx), 998491-UIM-B-1013 (Johnson Controls Unitary Products (York), TG8S*MP, TGLS*MP, GG8S*MP, GGLS*MP 80% AFUE single-stage gas furnaces) · checked 2026-08-25
- Installation Manual - Single Stage ECM Residential Gas Furnaces, TM9E Series (95% AFUE Multi-position), 1083163-UIM-A-0214 (Johnson Controls Unitary Products (York), TM9E*MP single-stage ECM 95% AFUE gas furnaces) · checked 2026-08-25
- Installation Manual - Two Stage Variable Speed ECM Residential Gas Furnaces, TM9V Series (96% AFUE Multi-position), 1083294-UIM-A-0114 (Johnson Controls Unitary Products (York), TM9V*MP two-stage variable-speed ECM 96% AFUE gas furnaces) · checked 2026-08-25
Code 6 amber flashes (YP9C modulating): Heat pump applications only: normal operation with a call for heat pump heating
Heat pump applications only: normal operation with a call for heat pump heating. Not a fault.
Manual wording: “Six Amber Flashes - (Heat Pump applications only) Normal operation with call for heat pump heating.”
Documented for: YP9C, YPLC modulating furnaces paired with a heat pump
Likely causes, most common first
- Normal dual-fuel / heat pump heating operation
When to call a technician
No service needed.
A York furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installation Manual - Modulating ECM Residential Gas Furnace with ECM Motor, Models YP9C*C / TP9C*C / CP9C*C / LP9C*C (Up to 98% Modulating Multi-position), 1083292-UIM-A-0114 (Johnson Controls Unitary Products (York), YP9C*C (York Affinity modulating), and the identical TP9C / CP9C / LP9C chassis) · checked 2026-08-25
Code 6 red flashes (YP9C modulating): Gas valve communication error
Gas valve communication error. The modulating gas valve and the control board have lost their data link, so the furnace cannot modulate or fire.
Manual wording: “Six Red Flashes - Gas valve communication error.”
Documented for: YP9C, YPLC modulating furnaces
Likely causes, most common first
- Loss of communication between the control board and the modulating gas valve
What you can safely check yourself
- Turn the furnace off at the service switch for a minute and back on once
When to call a technician
Modulating gas valve communication faults are a technician job - the valve, its harness and the board all have to be checked.
A York furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installation Manual - Modulating ECM Residential Gas Furnace with ECM Motor, Models YP9C*C / TP9C*C / CP9C*C / LP9C*C (Up to 98% Modulating Multi-position), 1083292-UIM-A-0114 (Johnson Controls Unitary Products (York), YP9C*C (York Affinity modulating), and the identical TP9C / CP9C / LP9C chassis) · checked 2026-08-25