Rheem Furnace Code 57
Soft lockout
High pressure switch open with the inducer on high speed. On a two-stage or modulating furnace the control will usually drop to low fire and keep heating (if the low pressure switch stays closed) rather than shut off completely.
Manual wording: “HIGH PRESSURE SWITCH OPEN, INDUCER ON HIGH SPEED ... This fault indicates that the high pressure switch is open when the inducer is energized at high speed.”
Documented for: (-)97V, (-)96V
Likely causes, most common first
- Blockage or improper termination in either the inlet or exhaust vents
- The flue vent length and/or number of elbows exceeds the maximum number specified
- Faulty or disconnected inducer
- Faulty control board (inducer relay)
- High altitude kit not installed in areas of high elevation
- Loose or faulty wiring
- Disconnected, blocked, split or cut pressure switch hoses
- Wind gusts (sporadic)
- Faulty pressure switch
What you can safely check yourself
- Check the outdoor intake and exhaust terminations for snow, ice, leaves or a nest.
- Check the condensate drain and trap for a clog.
- Power cycle once at the furnace switch after clearing any blockage.
When to call a technician
If the vent terminations are clear and 57 keeps coming back, have a technician check the inducer, pressure switch hoses and total vent length. Never jumper the switch.
A Rheem furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation Instructions for Upflow Condensing Modulating, Communicating Gas Furnaces - (-)97V Series (92-24161-126-04) (Rheem Manufacturing Company, R97V series modulating condensing gas furnace (and R98V); TABLE 18 normal operation codes, TABLE 19 fault codes, pages 94-104) · checked 2026-08-25
- Installation Instructions for 4 Position Condensing Two-Stage, Communicating Gas Furnaces - (-)96V Series (92-24161-124-08) (Rheem Manufacturing Company, R96V series and (-)(-)96MDV two-stage condensing gas furnaces; TABLE 19 normal operation codes, TABLE 20 fault codes, pages 111-120) · checked 2026-08-25