HVAC Code Lookup

Rheem Furnace Code D1

Hard lockout

No model data. The control cannot find the electronically stored model data that tells it how to run the blower, so the furnace will not operate in any mode. Usually the model data card is missing from the control board.

Manual wording: “NO MODEL DATA ... This code is displayed anytime there is no model data at the furnace. ... No operation (including thermostat) will be permitted without the model data.

Documented for: (-)97V, (-)96V communicating furnaces

Likely causes, most common first

  1. Model data card missing from connector P6 on the furnace control
  2. The original model data card was lost or disconnected when the furnace control was replaced

When to call a technician

This is a control-board / model-data-card problem. A technician must install the correct model data card for your furnace - the card is furnace-specific and using one from another unit can damage the heat exchanger.

A Rheem furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.