Rheem Furnace Code 33
Safety fault
Over-temperature switch (roll-out) open. A manually reset rollout limit has tripped, which means flames rolled out of the heat exchanger into the burner compartment. The manual describes this as a very serious problem that must be repaired before the furnace runs again.
Manual wording: “OVER-TEMPERATURE SWITCH (ROLL-OUT) OPEN ... This fault will occur when flames have rolled out of the normal area in the heat exchanger and into the burner compartment. This fault should rarely (if ever) be seen in the field and indicates a very serious problem.”
Documented for: (-)97V, (-)96V, (-)801S/(-)801P
Likely causes, most common first
- Insufficient venting through either the inlet or exhaust
- Loose or faulty wiring
- Unstable flame pattern
What you can safely check yourself
- Turn the furnace off at its switch and leave it off.
- If you smell gas or see soot, leave the building and call your gas utility from outside.
When to call a technician
Call a technician. Rollout means combustion products left the heat exchanger; the vent system, inducer, gaskets and heat exchanger all have to be inspected. Never push the rollout reset button and put the furnace back in service without a diagnosis.
A Rheem furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation Instructions for Upflow Condensing Modulating, Communicating Gas Furnaces - (-)97V Series (92-24161-126-04) (Rheem Manufacturing Company, R97V series modulating condensing gas furnace (and R98V); TABLE 18 normal operation codes, TABLE 19 fault codes, pages 94-104) · checked 2026-08-25
- Installation Instructions for 4 Position Condensing Two-Stage, Communicating Gas Furnaces - (-)96V Series (92-24161-124-08) (Rheem Manufacturing Company, R96V series and (-)(-)96MDV two-stage condensing gas furnaces; TABLE 19 normal operation codes, TABLE 20 fault codes, pages 111-120) · checked 2026-08-25