Warning

Low flame sense. The flame current the control reads from the flame sense rod is weak or marginal. The furnace keeps running normally, but if the signal falls further the code escalates to 13 (flame lost) or 11 (failed ignition).

Manual wording: “LOW FLAME SENSE ... The flame sense current from the flame sense rod at the furnace control (or I.F.C.) is weak or marginal at best.

Documented for: (-)97V, (-)96V, (-)801S/(-)801P

Likely causes, most common first

  1. The flame sense rod needs cleaning, is not properly connected, or its wiring to the control is shorted or open
  2. An improperly mounted or poorly grounded flame sensor

What you can safely check yourself

  • Nothing homeowner-serviceable - the flame sensor is inside the burner compartment. Book service before it turns into a no-heat call.

When to call a technician

Code 12 is an early warning. Have a technician clean or replace the flame sense rod and check the furnace ground before it becomes a lockout.

A Rheem furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.