Daikin Mini-Split Code UC
Warning
Address duplication of central remote controller. Two indoor units on the network were assigned the same centralized address.
Manual wording: “UC Address duplication of central remote controller”
Documented for: Systems using centralized control
Likely causes, most common first
- Address duplication of centralized remote controller
- Defective indoor unit PCB
When to call a technician
Addressing is set in the field by the installer. A technician has to change one unit's centralized address.
A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Service Manual - Multi-Split Type Air Conditioners RMXS-L Series (SiUS181631EA) (Daikin, RMXS48LVJU outdoor, BPMKS048A2U/049A3U branch provider, CTXG/CTXS/FTXS/CDXS/FDXS/FVXS/FFQ indoor units) · checked 2026-08-25