HVAC Code Lookup

Daikin Mini-Split Code C4

Warning

Indoor heat exchanger thermistor or related abnormality. The sensor reading the indoor coil temperature is sending a voltage above 4.96 V or below 0.04 V, which means it is open or shorted.

Manual wording: “C4 Indoor heat exchanger thermistor or related abnormality

Documented for: FTXS-L, FDXS-L, H-Series, FTXM-W/V, RMXS indoor units

Likely causes, most common first

  1. Disconnection of connector
  2. Defective thermistor
  3. Defective indoor unit PCB

What you can safely check yourself

  • Turn the system off at the breaker or disconnect switch and back on once

When to call a technician

C4 is a failed or disconnected temperature sensor inside the indoor unit. A technician has to measure the thermistor's resistance and reseat or replace it.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.