HVAC Code Lookup

Daikin Mini-Split Code L1

Hard lockout

Outdoor unit PCB abnormality on the inverter side. Overcurrent was detected during waveform output before the compressor started, or the current sensor misbehaved during synchronous start-up.

Manual wording: “L1 Outdoor unit PCB abnormality

Documented for: RMXS multi-split outdoor units

Likely causes, most common first

  1. IPM (power module) failure
  2. Current sensor failure
  3. Failure of IGBT or drive circuit
  4. Defective main PCB (A1P)

What you can safely check yourself

  • Turn the system off at the breaker or disconnect switch, wait a minute, and turn it back on once

When to call a technician

L1 is an inverter power-section failure. It ends in an outdoor board replacement by a technician.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.