Daikin Mini-Split Code H9

Warning

Outdoor temperature thermistor or related abnormality. The outdoor air temperature sensor is reading open or shorted (input voltage above 4.96 V or below 0.04 V).

Manual wording: “H9 Outdoor temperature thermistor or related abnormality

Documented for: RKS/RXS pair outdoor units, FTXM-W/V outdoor units, RMXS multi-split outdoor

Likely causes, most common first

  1. Disconnection of the connector for the thermistor
  2. Defective thermistor corresponding to the error code
  3. Defective outdoor unit PCB

What you can safely check yourself

  • Turn the system off at the breaker or disconnect switch and back on once

When to call a technician

The sensor and its connector are inside the outdoor unit. A technician has to check the thermistor's resistance and reseat or replace it.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.