HVAC Code Lookup

Daikin Mini-Split Code H8

Soft lockout

DC voltage or current sensor abnormality on 09/12 class units, or CT (current transformer) or related abnormality on 24/30/36 class units. The compressor is running above about 32 Hz but the sensed input current is implausibly low.

Manual wording: “H8 DC voltage / current sensor abnormality (09/12 class only) / CT or related abnormality (24/30/36 class only)

Documented for: RKS/RXS pair outdoor units, FTXM-W/V outdoor units

Likely causes, most common first

  1. Defective outdoor unit PCB
  2. Defective power module
  3. Broken or disconnected wiring
  4. Defective reactor

What you can safely check yourself

  • Turn the system off at the breaker or disconnect switch, wait a minute, and turn it back on once

When to call a technician

The manual's own remedy for H8 is replacing the outdoor unit PCB after current measurements. That is a technician job.

A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.