Daikin Mini-Split Code E5
Soft lockout
On pair (single-zone) systems, OL activation - the compressor's overload protector tripped. On RMXS multi-split systems the same code means compressor motor lock: the compressor will not start even in forced start-up mode.
Manual wording: “E5 OL activation (compressor overload)”
Documented for: FTXS-L, H-Series, FTXM-W/V pair systems (compressor overload); RMXS multi-split (compressor motor lock)
Likely causes, most common first
- Refrigerant shortage
- Defective stop valve or stop valve left closed
- Defective discharge pipe thermistor
- Defective electronic expansion valve or coil
- Defective four way valve or coil
- Water mixed in refrigerant
- Defective outdoor unit PCB
- Compressor lock or high differential pressure (multi-split)
- Incorrect UVW wiring (multi-split)
What you can safely check yourself
- Check the outdoor unit has clear airflow and is not blocked by snow, leaves or stored items
- Check and replace the indoor unit air filters
- Turn the system off at the breaker or disconnect switch and back on once
When to call a technician
E5 points at the compressor and the refrigerant circuit. It needs a technician with gauges - repeated restarts on an overloaded compressor will kill it.
A Daikin mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Service Manual - Inverter Pair FTXS-L Series / FDXS-L Series (SiUS091133) (Daikin, FTXS09/12/15/18/24/30/36LVJU wall mount, FDXS09/12LVJU ducted, RKS/RXS09-36LVJU outdoor) · checked 2026-08-25
- Service Manual - Inverter Pair Wall Mounted Type H-Series (SiUS04-924_A) (Daikin, FTXS30/36HVJU indoor, RKS30/36HVJU and RXS30/36HVJU outdoor) · checked 2026-08-25
- Service Manual - Inverter Pair Wall Mounted Type FTXM-W/V Series (SiUS042113EA) (Daikin, FTXM-W / FTXM-V (Daikin Atmosphera) wall-mount heat pump) · checked 2026-08-25
- Service Manual - Multi-Split Type Air Conditioners RMXS-L Series (SiUS181631EA) (Daikin, RMXS48LVJU outdoor, BPMKS048A2U/049A3U branch provider, CTXG/CTXS/FTXS/CDXS/FDXS/FVXS/FFQ indoor units) · checked 2026-08-25