HVAC Code Lookup

Ruud Furnace Code 68

Hard lockout

No blower communications. The furnace control cannot talk to the ECM blower motor at all. The furnace will not operate in any mode; if it was heating, the gas valve closes immediately.

Manual wording: “NO BLOWER COMMUNICATIONS ... The furnace control (I.F.C.) can not communicate with the blower motor.

Documented for: (-)97V, (-)96V

Likely causes, most common first

  1. The wires between the blower motor have been disconnected or there is a poor connection
  2. There is no line voltage to the motor
  3. The furnace model data is faulty or corrupted
  4. The motor has failed catastrophically

What you can safely check yourself

  • Make sure the blower door is fully closed and seated, and that the furnace switch and breaker are on.
  • Power cycle once at the furnace switch.

When to call a technician

Technician job: motor wiring, line voltage to the PFC choke and ECM motor, model data card and the motor itself all have to be checked.

A Ruud furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.