Ruud Furnace Code 2
Soft lockoutShown as: 2 blinks of the green status LED, repeating
Pressure switch circuit open - the switch failed to close (or stayed open) when the inducer ran. Usually a blocked or over-long vent, a bad inducer, or a pressure switch hose problem.
Manual wording: “2 Blinks - PS Circuit open”
Documented for: Standard furnaces with a green status LED, incl. RGRA/RGRB/RGTA/RGRS/RGTS/RGRT
Likely causes, most common first
- Blocked vent, excessive vent length or elbows, or a restricted heat exchanger
- Pressure switch, pressure switch hoses or wiring fault
- Inducer not running or wired incorrectly
- Excessive wind opening the pressure switch
- Water or moisture in the switches and hoses
What you can safely check yourself
- Go outside and check the vent and intake terminations for snow, ice, leaves or a nest.
- On a 90+ condensing furnace, check the condensate drain and trap for a clog.
- Reset power once at the furnace switch after clearing any blockage.
When to call a technician
If it returns, the inducer, pressure switch, hoses or vent run needs a technician. Never jumper a pressure switch.
A Ruud furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation Instructions for Upflow & Downflow/Horizontal High Efficiency Condensing Gas Furnaces - RGRA/RGRB/RGTA/RGRS/RGTS/RGRT Series (92-24161-16-19) (Rheem Manufacturing Company, RGRA/RGRB/RGTA/RGRS/RGTS/RGRT 90+ condensing furnaces using the UT Electronic Controls 1028-928 integrated furnace control; BLINK CODES (GREEN LED) block on the troubleshooting chart, page 56) · checked 2026-08-25