Mitsubishi Electric Mini-Split Code U8

Soft lockout

Outdoor fan motor protection stop. The board is not seeing the expected rotational speed from the DC outdoor fan motor - 100 rpm or below for 15 seconds at 68F or warmer outdoor air, or 50 rpm or below (or 1500 rpm or more) continuously for 1 minute.

Manual wording: “Outdoor fan motor - Abnormal if rotational frequency of the fan motor is not detected during DC fan motor operation.

Documented for: A-Control outdoor units (PUZ, MUZ, MXZ)

Likely causes, most common first

  1. Failure in the outdoor DC fan motor
  2. Failure in the outdoor controller board

What you can safely check yourself

  • Turn the power off at the breaker first, then look for leaves, ice, a stick or other debris jamming the outdoor fan blade
  • Clear snow and ice from around and on top of the outdoor unit
  • Turn the system back on at the breaker once

When to call a technician

If nothing is physically jamming the fan and U8 returns, the fan motor or the control board has failed. Never reach into the outdoor unit with power on. Call a technician.

A Mitsubishi Electric mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.