Mitsubishi Electric Mini-Split 4 Blinks

Hard lockoutShown as: Upper OPERATION INDICATOR lamp blinks 4 times, then 2.5 seconds off, repeating

Indoor control system error. The indoor electronic control board cannot read its own nonvolatile memory correctly.

Manual wording: “Indoor control system - It cannot properly read data in the nonvolatile memory of the indoor electronic control P.C. board.

Documented for: MSZ-GL and MSY-GL indoor units

Likely causes, most common first

  1. Defective indoor electronic control P.C. board

What you can safely check yourself

  • Turn the system off at the breaker, wait one minute, and turn it back on once

When to call a technician

The manual's only remedy is to replace the indoor electronic control P.C. board. Call a technician.

A Mitsubishi Electric mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.