Mitsubishi Electric Mini-Split: 6 Flashes

Code 6 blinks: Outdoor thermistor error

Soft lockoutShown as: Upper OPERATION INDICATOR lamp blinks 6 times, then 2.5 seconds off, repeating

Outdoor thermistor error. One of the outdoor unit temperature sensors reads short circuit or open circuit while the compressor is running.

Manual wording: “Outdoor thermistors - The outdoor thermistors short or open circuit during the compressor operation.

Documented for: MSZ-GL and MSY-GL indoor units paired with MUZ-GL or MUY-GL outdoor units

Likely causes, most common first

  1. Defective outdoor thermistor (discharge, defrost, ambient, fin or heat-exchanger sensor)
  2. Thermistor connector loose on the outdoor control board
  3. Broken thermistor lead wire

What you can safely check yourself

  • Turn the system off at the breaker, wait one minute, and turn it back on once

When to call a technician

Identifying which outdoor sensor failed requires opening the outdoor unit and reading its board LEDs. Call a technician.

A Mitsubishi Electric mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.