LG Mini-Split Code CH61
Soft lockoutShown as: Outdoor LED01 (red) blinks 6 times, LED02 (green) blinks 1 time
Outdoor unit condenser coil pipe temperature is too high. In cooling this means the outdoor unit is overheating; in heating it means the indoor coil is overheating. In both cases the system cannot get rid of the heat it is making.
Manual wording: “Condenser coil thermistor temperature is too high”
Documented for: All LG residential mini-split outdoor units
Likely causes, most common first
- Overload operation - indoor or outdoor fan restricted, screened, or blocked
- Heat exchanger (coil) contaminated with dirt, lint, cottonwood, or grass clippings
- Poor condenser pipe sensor assembly or burned sensor
- EEV connector displaced or poor EEV assembly
- Refrigerant overcharged
What you can safely check yourself
- Clear leaves, grass clippings, cottonwood, snow, or debris away from the outdoor coil and fan
- Remove anything stacked against or on top of the outdoor unit, and check there is clear space all around it
- Check and clean the indoor air filters
- Make sure the indoor supply and return grilles are open and unblocked
- Let the unit cool, then turn it off at the breaker for three minutes and back on
When to call a technician
If airflow is clear on both units and CH61 returns, the coil needs a proper cleaning or the charge and expansion valve need checking. Call a technician.
A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- MULTI F / MULTI F MAX Outdoor Unit Installation Manual (LG Electronics U.S.A., Inc., Multi F and Multi F MAX multi-zone heat pump outdoor units (LMU series) with standard wall-mount, Art Cool, cassette and ducted indoor units) · checked 2026-08-25
- Single Zone Four-Way Ceiling-Cassette Installation Manual (LG Electronics U.S.A., Inc., Single-zone four-way ceiling cassette indoor units with LUU090HV through LUU420HV outdoor units) · checked 2026-08-25
- Convertible Mid-Static Ducted LGRED Degree System Installation Manual (LG Electronics U.S.A., Inc., LGRED single-zone convertible mid-static ducted indoor units with LUU180HHV / LUU240HHV outdoor units) · checked 2026-08-25
- Defining Common Error Codes - Standard Wall-Mounted High-Efficiency Single Zone Systems (LG Electronics U.S.A. - Commercial Air Conditioning, LS091HSV and LS121HSV systems (LSN091HSV / LSN121HSV indoor units, LSU091HSV / LSU121HSV outdoor units)) · checked 2026-08-25
- Room Air Conditioner SVC Manual (General) - Trouble Shooting Guide with Error Code (LG Electronics, All LG single-zone room air conditioner / mini-split chassis (SW, SB, SC, S4, S5, SH, SA, SJ, SK)) · checked 2026-08-25
- LG Air Conditioner - Guide to Error Codes (LG USA Support help library) (LG Electronics U.S.A., Inc., LG residential single-split and multi-split air conditioners / heat pumps) · checked 2026-08-25