LG Mini-Split Code CH06

Soft lockoutShown as: Indoor unit LED1 (units place) blinks 6 times

Indoor unit outlet pipe sensor error. The thermistor on the indoor coil's outlet (gas side) refrigerant pipe is disconnected, shorted or open.

Manual wording: “Indoor unit outlet pipe temperature sensor is disconnected, shorted, or opened.

Documented for: All LG residential mini-split indoor units

Likely causes, most common first

  1. Sensor mis-wiring or short at the connector
  2. Moisture penetration into the sensor
  3. Bad sensor canning sheath (damaged sensor sheath or insulation)
  4. Sensor housing removed so the sensor is off the pipe
  5. Indoor unit PCB fault (only after the sensor itself checks good)

What you can safely check yourself

  • Turn the system off at the breaker for one minute, then back on, to see if the code clears
  • Check that the indoor unit's front panel and filter access door are fully closed and latched

When to call a technician

The sensor sits on the refrigerant piping inside the indoor unit. Replacing it is a technician job.

A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.