Hard lockoutShown as: Outdoor LED01 (red) blinks 6 times, LED02 (green) does not blink
Outdoor unit PCB EEPROM check sum error. The memory chip on the outdoor control board that stores the unit's identity and factory parameters failed its integrity check.
Manual wording: “Outdoor unit printed circuit board (PCB) EEPROM check sum error”
Documented for: All LG residential mini-split outdoor units
What you can safely check yourself
- Turn the system off at the breaker for three minutes and back on
When to call a technician
A failed EEPROM checksum means the outdoor control board cannot trust its own configuration. A technician has to replace the board.
A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- MULTI F / MULTI F MAX Outdoor Unit Installation Manual (LG Electronics U.S.A., Inc., Multi F and Multi F MAX multi-zone heat pump outdoor units (LMU series) with standard wall-mount, Art Cool, cassette and ducted indoor units) · checked 2026-08-25
- Single Zone Four-Way Ceiling-Cassette Installation Manual (LG Electronics U.S.A., Inc., Single-zone four-way ceiling cassette indoor units with LUU090HV through LUU420HV outdoor units) · checked 2026-08-25
- Convertible Mid-Static Ducted LGRED Degree System Installation Manual (LG Electronics U.S.A., Inc., LGRED single-zone convertible mid-static ducted indoor units with LUU180HHV / LUU240HHV outdoor units) · checked 2026-08-25
- Defining Common Error Codes - Standard Wall-Mounted High-Efficiency Single Zone Systems (LG Electronics U.S.A. - Commercial Air Conditioning, LS091HSV and LS121HSV systems (LSN091HSV / LSN121HSV indoor units, LSU091HSV / LSU121HSV outdoor units)) · checked 2026-08-25