HVAC Code Lookup

LG Mini-Split Code CH48

Soft lockoutShown as: Outdoor LED01 (red) blinks 4 times, LED02 (green) blinks 8 times

Outdoor unit condenser coil outlet (liquid line) thermistor is disconnected or shorted out.

Manual wording: “Outlet piping (liquid) of condenser is disconnected or has shorted out

Documented for: All LG residential mini-split outdoor units

Likely causes, most common first

  1. Sensor mis-wiring or short at the connector
  2. Moisture penetration into the sensor or bad canning sheath on the sensor wire

What you can safely check yourself

  • Turn the system off at the breaker for three minutes and back on

When to call a technician

The liquid line sensor is on refrigerant piping inside the outdoor cabinet. Technician only.

A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other LG codes