LG Mini-Split Code CH38
Hard lockoutShown as: Outdoor LED1 blinks 3 times, LED2 blinks 6 times (2-LED type; service manual lists this row as '36 (38)')
Refrigerant leakage detection - the system is low on refrigerant. LG's consumer support page states plainly that CH38 means the air conditioner is low on refrigerant (gas).
Manual wording: “Refrigerant leakage detection”
Documented for: LG residential mini-split outdoor units with refrigerant leak detection (including LSU363HLV-class dual inverter units)
Likely causes, most common first
- Pipe break damage
- Bad connection of the pipe (flare joints)
- Pipe damage due to corrosion
- Corrosion damage of the heat exchanger
- Compressor damage (crack)
- EEV body clogging
- Refrigerant shortage, including too little refrigerant added at install for the line length
What you can safely check yourself
- Turn the system off so the compressor is not running short of refrigerant until a technician can look at it
When to call a technician
A leak has to be found, repaired, and the system evacuated and recharged by weight. That is EPA-regulated work for a licensed technician - topping it off without finding the leak just repeats the failure.
A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.