HVAC Code Lookup

LG Mini-Split Code CH26

Hard lockoutShown as: Outdoor LED01 (red) blinks 2 times, LED02 (green) blinks 6 times

DC compressor position error. The inverter cannot detect the compressor rotor turning, so the compressor failed to start - it is seized, miswired, or the drive board cannot sense it.

Manual wording: “DC Compressor Position Error (Compressor failed to start properly)

Documented for: All LG residential mini-split outdoor units

Likely causes, most common first

  1. Poor connection of the compressor connector
  2. Compressor failure (seized, or not providing rotation)
  3. PCB failure

What you can safely check yourself

  • Turn the system off at the breaker for three minutes and back on to allow one clean restart attempt

When to call a technician

CH26 means the compressor is not turning. Checking compressor wiring, winding resistance and insulation is high-voltage technician work.

A LG mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources