Lennox Furnace Code E229

Status

Information only. The furnace lit on high fire instead of low fire. This happens either because the low pressure switch did not close, so the control sped up the inducer to close both switches and lit on high fire, or because continuous fan was running and the furnace lights on high fire for 60 seconds to warm the heat exchanger faster.

Manual wording: “Ignition on High Fire - Information Only.

Documented for: EL296UHE series

Likely causes, most common first

  1. Low pressure switch failing to close on a normal low-fire start, often from a partially restricted vent
  2. Continuous fan mode active at the start of the heat call, which is normal behavior

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice or debris if the code shows up repeatedly
  • Check the air filter and replace it if it is dirty

When to call a technician

On its own this code is informational and needs no action. If it appears on every heat call along with pressure switch codes such as E223 or E227, have a technician check the vent and inducer.

A Lennox furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.