Lennox Furnace Code 9
WarningShown as: 9 rapid flashes (1/2 second on, 1/2 second off), then the LED stays off for 3 seconds and repeats
The pressure prove switch did not close when the combustion air inducer started, or it opened part way through the heat demand.
Manual wording: “9 - Pressure Switch failed to close or opened during heat demand”
Documented for: ML180UHE, ML193UHE and other Lennox furnaces using SureLight integrated control 103217-03 or 107163-01
Likely causes, most common first
- Blocked or restricted intake or exhaust vent pipe
- Plugged condensate drain or trap backing water into the pressure switch tubing
- Cracked, kinked or disconnected pressure switch hose
- Weak or failed combustion air inducer
What you can safely check yourself
- Check the outdoor intake and exhaust pipes for snow, ice, leaves or nesting debris
- Check the condensate drain line and trap for a clog or standing water
- Check that the furnace door is fully seated
- Turn the furnace power switch off for 30 seconds and back on once
When to call a technician
If the vent is clear and the drain is clear and the code stays, the pressure switch, its tubing or the inducer needs testing. Never jumper a pressure switch.
A Lennox furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.