HVAC Code Lookup

Lennox Furnace Code E125

Hard lockout

The control failed its own self-check. This is an internal hardware error on the furnace control board, covering things like flame sense circuit faults and pin shorts. The control restarts if the error clears.

Manual wording: “Control failed self-check, internal error, failed hardware. Will restart if error recovers.

Documented for: EL296UHE and SLP98UHV series

Likely causes, most common first

  1. Hardware failure on the integrated furnace control board
  2. Flame sense circuit fault on the board
  3. Electrical noise or a power event that corrupted the control

What you can safely check yourself

  • Turn the furnace power switch off for 30 seconds and back on once to cycle power on the control

When to call a technician

If the code returns after a single power cycle, the control board is failing and needs to be replaced by a technician.

A Lennox furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Lennox codes