Hard lockout

The fuse on the control board has blown, so there is no 24 volt control power and the furnace will not run.

Manual wording: “Open fuse.

Documented for: Goodman GMVC96, GCVC96, GMVM97, GCVM97, GM9S80, GC9S80, GR9S80, GD9S80, GR9T96, GD9T96 (seven-segment display controls)

Likely causes, most common first

  1. Blown fuse
  2. Short in low voltage wiring
  3. Back of control board is touching mounting panel because standoffs are missing

What you can safely check yourself

  • Check the furnace breaker in the electrical panel and reset it once if tripped

When to call a technician

The fuse blew because of a short. Replacing it without finding the short just blows another one - have a technician trace the low-voltage wiring.

A Goodman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.