Goodman Furnace Code 5

Safety faultShown as: 5 flashes, then a pause, repeating

Flame sensed when there should be none. The control detected flame for more than about 4 seconds with the gas valve de-energized. The furnace shuts down and both blowers keep running.

Manual wording: “Flame Sensed>4.25 Seconds with Gas Valve De-Energized

Documented for: Goodman GMS8, GMH8, GDS8, GDH8, GHS8, GME8, GMES80, GCES80, GMSS92, GMSS96, GCSS96 (single red diagnostic LED)

Likely causes, most common first

  1. Short to ground in the flame sense circuit
  2. Lingering burner flame
  3. Slow closing gas valve

What you can safely check yourself

  • Turn the furnace off at its power switch and leave it off until a technician arrives

When to call a technician

A gas valve that may be leaking through, or a flame that will not go out, is an immediate technician call. Shut the furnace off and do not attempt any test yourself.

A Goodman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.