HVAC Code Lookup

Coleman Furnace: 8 Flashes

A Coleman furnace LED pattern starting with 8 flashes matches 2 documented codes: 8 red flashes, 8 red flashes (CP9C Echelon modulating). Watch the full pattern (short vs. long flashes) to tell them apart — all 2 are explained below.

Code 8 red flashes: The flame was lost five times

Soft lockoutShown as: Eight red flashes, then a two-second pause, repeating

The flame was lost five times (four recycles) during one heating cycle. The furnace locks out for one hour and then restarts.

Manual wording: “8 RED FLASHES: This fault is indicated if the flame is lost five times (four recycles) during the heating cycle. Check for low gas pressure, dirty or faulty flame sensor or faulty gas valve.

Documented for: TG8S, TGLS, TG9S, TM8X, TMLX, TM9X, TM8T, TM9T, TM8V, TM9V

Likely causes, most common first

  1. Low gas pressure
  2. Dirty or faulty flame sensor
  3. Faulty gas valve

What you can safely check yourself

  • Check that other gas appliances in the house still work
  • Replace a dirty air filter
  • Check the outside vent and intake pipes for blockage

When to call a technician

Flame sensor cleaning and gas pressure checks are done with the burners running and require a manometer. Call a technician.

A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Full page for Coleman code 8 red flashes

Code 8 red flashes (CP9C Echelon modulating): Lockout due to too many flame recycles - the flame was lost five times during a single heating cycle

Soft lockoutShown as: Eight red flashes, two-second pause, repeating

Lockout due to too many flame recycles - the flame was lost five times during a single heating cycle. The control locks out for one hour, then tries again.

Manual wording: “Eight Red Flashes - Lockout due to too many flame recycles. This flash code occurs if flame is lost five times during a single heating cycle.

Documented for: CP9C Echelon modulating furnaces

Likely causes, most common first

  1. Faulty gas valve
  2. Low gas pressure
  3. Dirty flame sensor

What you can safely check yourself

  • Check that other gas appliances in the house still work
  • Replace a dirty air filter

When to call a technician

Gas pressure and flame sensor checks require a manometer and live-burner access. Call a technician.

A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.