Coleman Furnace 8 Red Flashes
Soft lockoutShown as: Eight red flashes, then a two-second pause, repeating
The flame was lost five times (four recycles) during one heating cycle. The furnace locks out for one hour and then restarts.
Manual wording: “8 RED FLASHES: This fault is indicated if the flame is lost five times (four recycles) during the heating cycle. Check for low gas pressure, dirty or faulty flame sensor or faulty gas valve.”
Documented for: TG8S, TGLS, TG9S, TM8X, TMLX, TM9X, TM8T, TM9T, TM8V, TM9V
Likely causes, most common first
- Low gas pressure
- Dirty or faulty flame sensor
- Faulty gas valve
What you can safely check yourself
- Check that other gas appliances in the house still work
- Replace a dirty air filter
- Check the outside vent and intake pipes for blockage
When to call a technician
Flame sensor cleaning and gas pressure checks are done with the burners running and require a manometer. Call a technician.
A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation Manual - Residential Gas Furnace, Models TG9S*MP, GG9S*MP (95.5% AFUE Single Stage Multi-position), 364861-UIM-G-1211 (Johnson Controls Unitary Products (Coleman), TG9S*MP, GG9S*MP 95.5% AFUE single-stage multi-position gas furnaces) · checked 2026-08-25
- Installation Manual - Residential Gas Furnace, Models TG8S*MP, TGLS*MP, GG8S*MP, GGLS*MP (Single Stage Multi-position / Low NOx), 356485-UIM-G-1211 (Johnson Controls Unitary Products (Coleman), TG8S*MP, TGLS*MP, GG8S*MP, GGLS*MP 80% AFUE single-stage gas furnaces) · checked 2026-08-25
- Installation Manual - Residential Gas Furnace, Models TM8X*MP, TMLX*MP (Single Stage Multi-position / Low NOx with High-Efficiency Motors), 437642-UIM-F-1211 (Johnson Controls Unitary Products (Coleman), TM8X*MP, TMLX*MP 80% AFUE single-stage gas furnaces with high-efficiency motors) · checked 2026-08-25
- Installation Manual - Residential Gas Furnace, Models TM9V*MP (Two Stage Variable Speed ECM), 701379-UIM-B-1211 (Johnson Controls Unitary Products (Coleman), TM9V*MP two-stage variable-speed ECM gas furnaces) · checked 2026-08-25